ADWPCIXRSKU20 Intel, ADWPCIXRSKU20 Datasheet - Page 111

no-image

ADWPCIXRSKU20

Manufacturer Part Number
ADWPCIXRSKU20
Description
Manufacturer
Intel
Datasheet

Specifications of ADWPCIXRSKU20

Lead Free Status / Rohs Status
Supplier Unconfirmed
Intel® Server Board SE7320VP2
5.2.9.1
The mBMC is capable of supporting three control panel indicators: Power LED, Fault/Status
LED, and Chassis ID LED. The states of these indicators and how they relate to the
mBMC/chassis state are detailed below.
5.2.9.1.1
The BIOS controls the control panel Power LED as described in the table below.
Power Off
Power On
5.2.9.1.2
The following table shows mapping of sensors/faults to the LED state.
Green
Amber
Off
Critical Condition - Any critical or non-recoverable threshold crossing associated with the
following events:
Non-Critical Condition
Revision 2.1
Color
State
Temperature, voltage, or fan critical threshold crossing
Critical Event Logging errors, including System Memory Uncorrectable ECC errors and
FSB Bus errors
Temperature, voltage, or fan non-critical threshold crossing
Chassis intrusion
Solid
Blink
Solid
Blink
Solid
Condition
Non-ACPI
Non-ACPI
Power Mode
Control Panel Indicators
Power LED
Fault / Status LED
System ready
System ready, but degraded: CPU disabled (not supported with the Server Board
SE7320VP2)
Critical failure: critical fan, voltage, or temperature state
Non-critical failure: non-critical fan, voltage, or temperature state
System not ready: POST error / NMI event / CPU or terminator missing
OFF
ON
LED
Table 52. SSI Power LED Operation
Intel order number C91056-002
Table 53. Fault / Status LED
System power is off, and the BIOS has not initialized the chipset.
System power is on, but the BIOS has not yet initialized the chipset.
When
Description
Platform Management
111