AD9510BCPZ Analog Devices Inc, AD9510BCPZ Datasheet - Page 43

IC CLOCK DIST 8OUT PLL 64LFCSP

AD9510BCPZ

Manufacturer Part Number
AD9510BCPZ
Description
IC CLOCK DIST 8OUT PLL 64LFCSP
Manufacturer
Analog Devices Inc
Type
Fanout Buffer (Distribution), Divider, PLLr
Datasheet

Specifications of AD9510BCPZ

Number Of Circuits
1
Ratio - Input:output
2:8
Differential - Input:output
Yes/Yes
Input
Clock
Output
CMOS, LVDS, LVPECL
Frequency - Max
1.2GHz
Voltage - Supply
3.135 V ~ 3.465 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
64-LFCSP
Frequency-max
1.2GHz
Clock Ic Type
Clock Distribution
Ic Interface Type
Serial
Frequency
1.2GHz
No. Of Outputs
8
No. Of Multipliers / Dividers
8
Supply Voltage Range
3.135V To 3.465V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
AD9510-VCO/PCBZ - BOARD EVALUATION FOR AD9510AD9510/PCBZ - BOARD EVALUATION FOR AD9510
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD9510BCPZ
Manufacturer:
AD
Quantity:
855
Part Number:
AD9510BCPZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
update command, the update simultaneously enables all register
changes since any previous update.
Phase offsets or divider synchronization will not become
effective until a SYNC is issued (see the Single-Chip
Synchronization section).
Read
If the instruction word is for a read operation (I15 = 1b), the
next N × 8 SCLK cycles clock out the data from the address
specified in the instruction word, where N is 1 to 4 as
determined by W1:W0. The readback data is valid on the falling
edge of SCLK.
The default mode of the AD9510 serial control port is
unidirectional mode; therefore, the requested data appears on
the SDO pin. It is possible to set the AD9510 to bidirectional
mode by writing the SDO enable register at 00h<7> = 1b. In
bidirectional mode, the readback data appears on the SDIO pin.
A readback request reads the data that is in the serial control
port buffer area, not the active data in the AD9510’s actual
control registers.
The AD9510 uses Addresses 00h to 5Ah. Although the AD9510
serial control port allows both 8-bit and 16-bit instructions, the
8-bit instruction mode provides access to five address bits (A4
to A0) only, which restricts its use to the address space 00h to
01F. The AD9510 defaults to 16-bit instruction mode on power-
up. The 8-bit instruction mode (although defined for this serial
control port) is not useful for the AD9510; therefore, it is not
discussed further in this data sheet.
THE INSTRUCTION WORD (16 BITS)
The MSB of the instruction word is R/
whether the instruction is a read or a write. The next two bits,
W1:W0, indicate the length of the transfer in bytes. The final 13
bits are the address (A12:A0) at which to begin the read or write
operation.
For a write, the instruction word is followed by the number of
bytes of data indicated by Bits W1:W0, which is interpreted
according to Table 20.
Figure 45. Relationship Between Serial Control Port Register Buffers and
SCLK
SDIO
SDO
CSB
SERIAL
CONTROL
PORT
Control Registers of the AD9510
REGISTERS
UPDATE
5Ah <0>
W
, which indicates
AD9510
CORE
Rev. A | Page 43 of 60
Table 20. Byte Transfer Count
W1
0
0
1
1
A12:A0: These 13 bits select the address within the register map
that is written to or read from during the data transfer portion
of the communications cycle. The AD9510 does not use all of
the 13-bit address space. Only Bits A6:A0 are needed to cover
the range of the 5Ah registers used by the AD9510. Bits A12:A7
must always be 0b. For multibyte transfers, this address is the
starting byte address. In MSB first mode, subsequent bytes
increment the address.
MSB/LSB FIRST TRANSFERS
The AD9510 instruction word and byte data may be MSB first
or LSB first. The default for the AD9510 is MSB first. The LSB
first mode may be set by writing 1b to Register 00h<6>. This
takes effect immediately (since it only affects the operation of
the serial control port) and does not require that an update be
executed. Immediately after the LSB first bit is set, all serial
control port operations are changed to LSB first order.
When MSB first mode is active, the instruction and data bytes
must be written from MSB to LSB. Multibyte data transfers in
MSB first format start with an instruction byte that includes the
register address of the most significant data byte. Subsequent
data bytes must follow in order from high address to low
address. In MSB first mode, the serial control port internal
address generator decrements for each data byte of the
multibyte transfer cycle.
When LSB_First = 1b (LSB first), the instruction and data bytes
must be written from LSB to MSB. Multibyte data transfers in
LSB first format start with an instruction byte that includes the
register address of the least significant data byte followed by
multiple data bytes. The serial control port internal byte address
generator increments for each byte of the multibyte transfer
cycle.
The AD9510 serial control port register address decrements
from the register address just written toward 0000h for
multibyte I/O operations if the MSB first mode is active
(default). If the LSB first mode is active, the serial control port
register address increments from the address just written
toward 1FFFh for multibyte I/O operations.
Unused addresses are not skipped during multibyte I/O
operations; therefore, it is important to avoid multibyte I/O
operations that would include these addresses.
W0
0
1
0
1
Bytes to Transfer
1
2
3
Streaming mode
AD9510

Related parts for AD9510BCPZ