K3HB-SSD 24VACVDC Omron, K3HB-SSD 24VACVDC Datasheet - Page 2

SENS LINEAR METER DC PROCES INPT

K3HB-SSD 24VACVDC

Manufacturer Part Number
K3HB-SSD 24VACVDC
Description
SENS LINEAR METER DC PROCES INPT
Manufacturer
Omron
Series
K3HBr
Type
Linear Sensor Meterr
Datasheets

Specifications of K3HB-SSD 24VACVDC

Measuring Range
0 ~ 20mA, 0 ~ 10V
Display Style
Green, Red Characters, Black Background
Display Type
LCD
Display Face Size
3.78" L x 1.89" W (96.0 x 48.0mm)
Display Digits
5
Display Digits - Height
0.193" (4.90mm), 0.559" (14.20mm)
Backlight
Green, Red
Mounting Type
Panel Mount
Termination
Screw Terminals
Voltage - Supply
24VAC/DC
Power Consumption
7W
Svhc
No SVHC (15-Dec-2010)
External Depth
95mm
External Length / Height
48mm
Ip/nema Rating
IP20
Operating Temperature Max
55°C
Operating Temperature Min
-10°C
Supply Voltage
RoHS Compliant
Approval Bodies
CE, CRUus, UL
Current Consumption
50mA
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
High-speed, High-precision
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
K3HB-SSD24VACVDC
K3HBSSD24VACVDC
Features
Red-Green Display Allows Easy Recognition
of Judgment Results
• The measurement value display can be set to switch be-
Position Meter Enables Easy Monitoring of
Operating Status Trends
• The present value with respect to the measurement or dis-
Many Measurement and Discrimination
Functions Using External Event Input
• Offers a wide variety of application possibilities, such detec-
High-speed Sampling at 50 Times per Second
(20 ms)
• Provides an input sampling cycle at least three times faster
Note: The K3HB-S Linear Sensor Indicator features high-speed re-
2
tween red and green in accordance with the status of com-
parative outputs. This means that the status can be
ascertained at a distance.
play range (full scale) can be viewed on a bar display. The
operating status can be grasped intuitively, allowing easy
judgement of levels and threshold values.
tion and judgement while synchronizing on an external sig-
nal.
than earlier models (12.5 times faster for temperature input
models) at 50 times/second (see note). In addition to im-
proved response times for judgement output and transfer
output, average processing can be used to increase the sta-
bility of measurements.
Measurement value
sponse of 2,000 times/second.
Measurement value
96
TIMING
TIMING
input
input
Peak/bottom hold
measurement
Sampling at 15 times/second
Input
OFF
MAX/MIN
Digital Indicators
HH
LL
H
P
L
Input
OFF
ON
ON
Max
B
Min
L
T-ZR
Zero
CMW
Hold
LEVEL
a1
b1
TG
T
TIMING
Timing of
internal
sampling
MODE
Measurement
(b1−a1)
HH
input
LL
Time
'a2
H
L
OFF
Input
value
ON
SHIFT
Sampling hold value
100
'b2
K3HB Series (Analog Input Series)
Peak-to-peak value
0
UP
(b2−a2)
Sampling at 50 times/second
Time
Peak value
Time
Peak-to-peak hold
measurement
Position meter
Sampling
measurement
Peak hold value
Bottom hold value
Timing of
internal
sampling
Time
Time
Short Body with Depth of Only 95 mm (from
Behind the Front Panel)
• A short body of only 95 mm (see note) contributes to the de-
Note: Depth of DeviceNet models is 97 mm.
Select a Comparative Output Pattern to Suit
the Discrimination or Control Application
• The output pattern for comparative outputs can be selected.
Note: The HH, H, L, or LL outputs must be set in that order for the
Lineup Includes DeviceNet Models Enabling
High-speed Data Communications with PLCs
without Special Programming
• DeviceNet compliance enables high-speed data transmis-
velopment of slimmer and smaller control panels and instal-
lations.
In addition to high/low comparison with set values, output
based on level changes is also possible. (Use the type of out-
put pattern appropriate for the application.)
sion by allocating setting and monitoring parameters in the
I/O memory of the PLC. This capability greatly reduces labor
spent in developing communications programs.
Output HH
Output H
Output PASS
Output L
Output LL
Output HH
Output H
Output PASS
Output L
Output LL
Comparative
set value HH
Comparative
set value H
Comparative
set value L
Comparative
set value LL
Comparative
set value HH
Comparative
set value H
Comparative
set value L
Comparative
set value LL
zone outputs to output correctly.
(This is because the comparative set values and outputs for
standard and level outputs are in a 1-to-1 relationship, whereas
the meaning of zone outputs depends on the settings of all the
comparative set values.)
(The depth is 100 mm when mounted to the terminal cover.)
Standard Output
Zone Output
P
P
Zero
Zero
DeviceNet
Depth: 95 mm (See note.)
Master
H
Measurement
Measurement
K3HB
Digital Indicators
value
ON
OFF
value
ON
OFF
Higher
Lower
Higher
Lower
Output HH
Output H
Output PASS
Output L
Output LL
Comparative
set value HH
Comparative
set value H
Comparative
set value L
Comparative
set value LL
Level Output
Ethernet
DeviceNet
Configurator
than earlier
shorter
models
27%
Measurement
value
ON
OFF
Higher
Lower