74SSTUA32866BFG8 IDT, Integrated Device Technology Inc, 74SSTUA32866BFG8 Datasheet - Page 11

no-image

74SSTUA32866BFG8

Manufacturer Part Number
74SSTUA32866BFG8
Description
Manufacturer
IDT, Integrated Device Technology Inc
Datasheet

Specifications of 74SSTUA32866BFG8

Logic Family
SSTU
Logical Function
Registered Buffer
Number Of Elements
1
Number Of Bits
25
Number Of Inputs
25
Number Of Outputs
25
High Level Output Current
-8mA
Low Level Output Current
8mA
Propagation Delay Time
2.4ns
Operating Supply Voltage (typ)
1.8V
Operating Supply Voltage (max)
1.9V
Operating Supply Voltage (min)
1.7V
Clock-edge Trigger Type
Posit/Negat-Edge
Polarity
Non-Inverting
Technology
CMOS
Frequency (max)
410(Min)MHz
Mounting
Surface Mount
Pin Count
96
Operating Temp Range
0C to 70C
Operating Temperature Classification
Commercial
Lead Free Status / RoHS Status
Compliant
OPERATING CHARACTERISTICS, T
NOTES:
1. The RESET and Cx inputs of the device must be held at valid levels (not floating) to ensure proper device operation.
2. The differential inputs must not be floating unless RESET is LOW.
DC ELECTRICAL CHARACTERISTICS OVER OPERATING RANGE
Following Conditions Apply Unless Otherwise Specified:
Operating Condition: T
NOTE:
1. Each V
IDT74SSTUA32866
1.8V CONFIGURABLE REGISTERED BUFFER WITH ADDRESS-PARITY TEST
Symbol
Symbol
V
V
I
V
V
I
DDD
V
V
V
V
V
V
I
C
V
V
V
I
DD
V
T
OH
I
REF
OH
OL
OL
ICR
DD
TT
I
IH
IH
IH
ID
IL
IL
IL
A
I
I
REF
pin (A3, T3) should be tested independently, with the other pin open circuit.
Parameter
Output HIGH Voltage
Output LOW Voltage
All Inputs
Static Standby
Static Operating
Dynamic Operating
(Clock Only)
Dynamic Operating
(Per Each Data Input)
Data Inputs, CSR, PAR_IN
CLK and CLK
RESET
Parameter
Supply Voltage
Reference Voltage
Termination Voltage
Input Voltage
AC High-Level Input Voltage
AC Low-Level Input Voltage
DC High-Level Input Voltage
DC Low-Level Input Voltage
High-Level Input Voltage
Low-Level Input Voltage
Common Mode Input Voltage
Differential Input Voltage
High-Level Output Current
Low-Level Output Current
Operating Free-Air Temperature
(1)
A
= 0°C to +70°C, V
DD
Test Conditions
I
I
V
I
I
I
CLK and CLK Switching 50% Duty Cycle.
I
V
50% Duty Cycle. One Data Input Switching at
Half Clock Frequency, 50% Duty Cycle.
V
V
OH
OL
O
O
O
O
I
I
ICR
I
= V
= 0, V
= 0, V
= V
= 0, V
= 0, V
= V
Data Inputs, CSR, DCS,
PAR_IN
RESET, Cx
RESET, Cx
CLK, CLK
Data Outputs, PPO
Data Outputs, PPO, QERR
CLK, CLK
= 1.8V ± 0.1V
= 6 mA
= –6 mA
= 0.9V, V
IH (AC)
DD
DD
DD
DD
DD
DD
or GND; V
or GND
= 1.9V, RESET = V
= 1.8V, RESET = V
= 1.8V, RESET = V
= 1.9V, RESET = GND
or V
ID
IL (AC)
= 600mV
DD
, CLK and CLK Switching at
= 1.9V
A
= 25ºC
DD
DD
DD
, V
, V
,
11
V
V
V
REF
REF
I
I
0.49 * V
0.65 * V
REF
= V
= V
0.675
Min.
+ 250mV
+ 125mV
600
1.7
– 40mV
0
0
IH (AC)
IH (AC)
DD
DD
(1,2)
or V
or V
IL (AC)
IL (AC)
1:1 Mode
1:2 Mode
,
0.5 * V
V
Typ.
REF
DD
COMMERCIAL TEMPERATURE RANGE
Min.
1.2
2.5
2
V
V
V
REF
REF
0.51 * V
0.35 * V
REF
1.125
Max.
Typ.
V
– 250mV
– 125mV
1.9
+ 40mV
–8
70
DD
8
DD
DD
Max.
100
0.5
3.5
±5
40
3
MHz/Data
μA/Clock
μA/Clock
Unit
mV
mA
°C
V
V
V
V
V
V
V
V
MHz
Input
Unit
mA
μA
μA
pF
V
V

Related parts for 74SSTUA32866BFG8