82V2088BBG IDT, Integrated Device Technology Inc, 82V2088BBG Datasheet - Page 47

no-image

82V2088BBG

Manufacturer Part Number
82V2088BBG
Description
Manufacturer
IDT, Integrated Device Technology Inc
Datasheet

Specifications of 82V2088BBG

Screening Level
Industrial
Mounting
Surface Mount
Operating Temperature (min)
-40C
Operating Temperature (max)
85C
Lead Free Status / RoHS Status
Compliant
OCTAL CHANNEL T1/E1/J1 LONG HAUL/SHORT HAUL LINE INTERFACE UNIT
Table-44 MAINT4: Maintenance Function Control Register 4
Table-45 MAINT5: Maintenance Function Control Register 5
Table-46 MAINT6: Maintenance Function Control Register 6
RIBLBA[7:0]
RIBLBD[7:0]
EXZ_DEF
ERR_SEL
CNT_TRF
ERR_INS
BPV_INS
CNT_MD
Symbol
Symbol
Symbol
-
(R/W, Address = 0EH,2EH,4EH,6EH,8EH,AEH,CEH,EEH)
(R/W, Address = 0FH,2FH,4FH,6FH,8FH,AFH,CFH,EFH)
(R/W, Address = 10H,30H,50H,70H,90H,B0H,D0H,F0H)
7-0
7-0
3-2
Bit
Bit
Bit
7
6
5
4
1
0
(000)00001 Defines the user-programmable receive Inband Loopback activate code. The default selection is 00001.
(00)001001 Defines the user-programmable receive Inband Loopback deactivate code. The default selection is 001001.
Default
Default
Default
00
0
0
0
0
0
0
These bits choose which type of error will be counted
RIBLBA[7:0] form the 8-bit repeating code
RIBLBA[6:0] form the 7-bit repeating code
RIBLBA[5:0] form the 6-bit repeating code
RIBLBA[4:0] form the 5-bit repeating code
RIBLBD[7:0] form the 8-bit repeating code
RIBLBD[6:0] form the 7-bit repeating code
RIBLBD[5:0] form the 6-bit repeating code
RIBLBD[4:0] form the 5-bit repeating code
Reserved.
BPV error insertion
A ‘0’ to ‘1’ transition on this bit will cause a single bipolar violation error to be inserted into the transmit data
stream. This bit must be cleared and set again for a subsequent error to be inserted.
PRBS/QRSS logic error insertion
A ‘0’ to ‘1’ transition on this bit will cause a single PRBS/QRSS logic error to be inserted into the transmit PRBS/
QRSS data stream. This bit must be cleared and set again for subsequent error to be inserted.
EXZ definition select
= 0: ANSI
= 1: FCC
= 00: the PRBS logic error is counted by a 16-bit error counter.
= 01: the EXZ error is counted by a 16-bit error counter.
= 10: the Received CV (BPV) error is counted by a 16-bit error counter.
= 11: both CV (BPV) and EXZ errors are counted by a 16-bit error counter.
Counter operation mode select
= 0: Manual Report Mode
= 1: Auto Report Mode
= 0: Clear this bit for the next ‘0’ to ‘1’ transition on this bit.
= 1: Error counting result is transferred to CNT0 and CNT1 and the error counter is reset.
47