82V2081PPG8 IDT, Integrated Device Technology Inc, 82V2081PPG8 Datasheet - Page 42

82V2081PPG8

Manufacturer Part Number
82V2081PPG8
Description
Manufacturer
IDT, Integrated Device Technology Inc
Datasheet

Specifications of 82V2081PPG8

Number Of Transceivers
1
Screening Level
Industrial
Mounting
Surface Mount
Package Type
TQFP
Operating Temperature (min)
-40C
Operating Temperature (max)
85C
Lead Free Status / RoHS Status
Compliant
SINGLE CHANNEL T1/E1/J1 LONG HAUL/SHORT HAUL LINE INTERFACE UNIT
Table-41 MAINT4: Maintenance Function Control Register 4
Table-42 MAINT5: Maintenance Function Control Register 5
Table-43 MAINT6: Maintenance Function Control Register 6
RIBLBA[7:0]
RIBLBD[7:0]
EXZ_DEF
ERR_SEL
CNT_TRF
ERR_INS
BPV_INS
CNT_MD
Symbol
Symbol
Symbol
-
(R/W, Address = 11H)
(R/W, Address = 12H)
(R/W, Address = 13H)
7-0
7-0
3-2
Bit
Bit
Bit
7
6
5
5
1
0
(000)00001 Defines the user-programmable receive Inband loopback activate code. The default selection is 00001.
(00)001001 Defines the user-programmable receive Inband loopback deactivate code. The default selection is 001001.
Default
Default
Default
00
0
0
0
0
0
0
These bits choose which type of error will be counted
RIBLBA [7:0] form the 8-bit repeating code
RIBLBA [6:0] form the 7-bit repeating code
RIBLBA [5:0] form the 6-bit repeating code
RIBLBA [4:0] form the 5-bit repeating code
RIBLBD [7:0] form the 8-bit repeating code
RIBLBD [6:0] form the 7-bit repeating code
RIBLBD [5:0] form the 6-bit repeating code
RIBLBD [4:0] form the 5-bit repeating code
Reserved.
BPV error insertion
A ‘0’ to ‘1’ transition on this bit will cause a single bipolar violation error to be inserted into the transmit data stream.
This bit must be cleared and set again for a subsequent error to be inserted.
PRBS logic error insertion
A ‘0’ to ‘1’ transition on this bit will cause a single PRBS logic error to be inserted into the transmit PRBS data stream.
This bit must be cleared and set again for a subsequent error to be inserted.
EXZ definition select
= 0: ANSI
= 1: FCC
= 00: The PRBS logic error is counted by a 16-bit error counter.
= 01: The EXZ error is counted by a 16-bit error counter.
= 10: The Received CV (BPV) error is counted by a 16-bit error counter.
= 11: Both CV (BPV) and EXZ errors are counted by a 16-bit error counter.
Counter operation mode select
= 0: Manual Report mode
= 1: Auto Report mode
= 0: Clear this bit for the next ‘0’ to ‘1’ transition on this bit.
= 1: Error counting result is transferred to CNT0 and CNT1 and the error counter is reset.
42
Description
Description
Description
TEMPERATURE RANGES
INDUSTRIAL