U3606A AGILENT TECHNOLOGIES, U3606A Datasheet - Page 4

MULTIMETER, DIGITAL, BENCH, 5-1/2 DIGIT

U3606A

Manufacturer Part Number
U3606A
Description
MULTIMETER, DIGITAL, BENCH, 5-1/2 DIGIT
Manufacturer
AGILENT TECHNOLOGIES
Datasheets

Specifications of U3606A

Dmm Type
Bench
Voltage Measuring Range Dc
100mV To 1000V
Voltage Measuring Range Ac
100mV To 750V
Current Measuring Range Dc
10mA To 3A
Current Measuring Range Ac
10mA To 3A
Lead Free Status / RoHS Status
na
Digital multimeter specifications
Specification assumptions:
• Specifications stated are after 60-minutes of warm-up and for 5½-digit resolution
• One-year calibration cycle, with calibration temperature of 18 °C to 20 °C
• Operating temperature: 18 °C to 28 °C (64.4 °F to 82.4 °F)
• Accuracy is expressed as ±(% of reading + % of range)
• Temperature coefficient: Add [0.1 x (the specified accuracy) / °C] for 0 °C to 18 °C and 28 °C to 55 °C
• Relative humidity (RH) up to 80% at 30 °C, proportional to 50% for 30 °C to 55 °C
DC specifications
1. 20% over-range on all ranges, except for 1000 V
2. Relative to calibration standards.
3. Any current measurement greater than 500 mA will have a temporary thermo-effect. If you wish to measure a lower current or offset current im-
4. Specifications stated are for 2-wire resistance measurements using Null math operation. Without Null, add a 0.2 Ω error. To eliminate noise interfer-
5. Specifications stated are for the voltage measured at the input terminals only. The test current (1 mA) is typical. Variation in the current source will
6. Specifications stated are for open test lead measurements with film capacitor or better, using Null math operation.
Function
DC voltage
DC current
Resistance
Continuity
Diode
Capacitance
mediately after a high-current measurement, ensure that the U3606A has cooled down.
ence which may be induced by the test leads, a shielded test cable is recommended for resistances above 100 kΩ.
create some variation in the voltage dropped across a diode junction.
5
3
4
6
Range
100.000 mV
1.00000 V
10.0000 V
100.000 V
1000.00 V
10.0000 mA
100.000 mA
1.00000 A
3.0000 A
100.000 Ω
1000.00 Ω
10.0000 kΩ
100.000 kΩ
1.00000 MΩ
10.0000 MΩ
100.000 MΩ
1.0000 kΩ
1.0000 V
1.000 nF
10.00 nF
100.00 nF
1.000 µF
10.00 µF
100.0 µF
1000 µF
10000 µF
1
Test current
or burden
voltage
< 0.2 V
< 0.2 V
< 0.3 V
< 0.7 V
0.83 mA
0.83 mA
100 µA
10 µA
900 nA
205 nA
205 nA || 10 MΩ
0.83 mA
0.83 mA
0.75 µA
0.75 µA
8.3 µA
83 µA
83 µA
83 µA
0.83 mA
0.83 mA
dc
range.
24 hours
23 ºC ± 1 ºC
0.012 + 0.008
0.012 + 0.005
0.012 + 0.005
0.012 + 0.005
0.012 + 0.005
0.05 + 0.015
0.05 + 0.005
0.05 + 0.007
0.05 + 0.007
0.04 + 0.008
0.04 + 0.005
0.04 + 0.005
0.04 + 0.005
0.05 + 0.005
0.20 + 0.005
1.60 + 0.005
0.04 + 0.005
0.04 + 0.005
Accuracy ±(% of reading + % of range)
4
2
90 days
23 ºC ± 5 ºC
0.015 + 0.008
0.015 + 0.005
0.015 + 0.005
0.015 + 0.005
0.015 + 0.005
0.05 + 0.015
0.05 + 0.005
0.05 + 0.007
0.05 + 0.007
0.04 + 0.008
0.04 + 0.005
0.04 + 0.005
0.04 + 0.005
0.05 + 0.005
0.20 + 0.005
1.60 + 0.005
0.04 + 0.005
0.04 + 0.005
1 year
23 ºC ± 5 ºC
0.025 + 0.008
0.025 + 0.005
0.025 + 0.005
0.025 + 0.005
0.025 + 0.005
0.05 + 0.015
0.05 + 0.005
0.15 + 0.007
0.15 + 0.007
0.05 + 0.008
0.05 + 0.005
0.05 + 0.005
0.05 + 0.005
0.06 + 0.005
0.25 + 0.005
2.00 + 0.005
0.05 + 0.005
0.05 + 0.005
2.0 + 0.8
1.0 + 0.5
1.0 + 0.5
1.0 + 0.5
1.0 + 0.5
1.0 + 0.5
1.0 + 0.5
2.0 + 0.5
Temperature
coefficient
0 ºC to 18 ºC
28 ºC to 55 ºC
0.0015 + 0.0005
0.0010 + 0.0005
0.0020 + 0.0005
0.0015 + 0.0005
0.0015 + 0.0005
0.0060 + 0.0005
0.0060 + 0.0005
0.0100 + 0.0005
0.0150 + 0.0010
0.0050 + 0.0005
0.0050 + 0.0005
0.0050 + 0.0005
0.0050 + 0.0005
0.0050 + 0.0005
0.0150 + 0.0005
0.1500 + 0.0005
0.0050 + 0.0005
0.0050 + 0.0005
0.02 + 0.001
0.02 + 0.001
0.02 + 0.001
0.02 + 0.001
0.02 + 0.001
0.02 + 0.001
0.02 + 0.001
0.02 + 0.001