U3606A AGILENT TECHNOLOGIES, U3606A Datasheet - Page 10

MULTIMETER, DIGITAL, BENCH, 5-1/2 DIGIT

U3606A

Manufacturer Part Number
U3606A
Description
MULTIMETER, DIGITAL, BENCH, 5-1/2 DIGIT
Manufacturer
AGILENT TECHNOLOGIES
Datasheets

Specifications of U3606A

Dmm Type
Bench
Voltage Measuring Range Dc
100mV To 1000V
Voltage Measuring Range Ac
100mV To 750V
Current Measuring Range Dc
10mA To 3A
Current Measuring Range Ac
10mA To 3A
Lead Free Status / RoHS Status
na
Power supply specifications
Specification assumptions:
• Specifications stated are after 60-minutes of warm-up with no load
• Operating temperature: 18 °C to 28 °C (64.4 °F to 82.4 °F)
• Accuracy is expressed as ±(% of output + offset) at 23 °C ± 5 °C
• Temperature coefficient: Add [0.1 x (the specified accuracy) / °C] for 0 °C to 18 °C and 28 °C to 55 °C
• Relative humidity (RH) up to 80% at 30 °C, proportional to 50% for 30 °C to 55 °C
DC power supply specifications
1. Contacts and leads resistance may contribute an additional error of 6 mV/A (typical).
2. Average time for the detection of OVP or OCP condition.
3. Refer to U3606A User’s and Service Guide (U3606-90013); CV noise effect measurement on page 166.
Output ratings
Programming accuracy
1 year (@ 23 ºC ± 5 ºC), ±(% of output + offset)
Readback accuracy
1 year over GPIB and USB or front panel with respect to
actual output (@ 23 ºC ± 5 ºC), ±(% of output + offset)
Ripple and noise
With outputs ungrounded, or with either output
terminal grounded, 20 Hz to 1 MHz
Front terminal load regulation
±(% of output + offset)
Rear terminal load regulation
±(% of output + offset)
Line regulation
Programming resolution
Readback resolution
Front panel resolution
Transient response time
Command processing time
Overvoltage protection (for CC mode)
Overcurrent protection (for CV mode)
3
• Range S1: 0 V to 30 V, 0 A to 1 A
• Range S2: 0 V to 8 V, 0 A to 3 A
• 0.05% + 5 mV
• 0.15% + 3 mA
• 0.05% + 5 mV
• 0.15% + 3 mA
• < 2 mV
• < 1 mA
• < 3 mV
• < 0.03% + 0.3 mA
• < 0.01% + 3 mV
• < 0.03% + 0.3 mA
Voltage: 3 mV
Current: 1.5 mA
1 mV, 0.1 mA
1 mV, 0.1 mA
1 mV, 0.1 mA
Less than 450 ms for output to recover to within 50 mV following a
change in output current from full load to half load or vice versa
Average time for output voltage to begin to change after receipt of
digital data when instrument is connected directly to the USB or GPIB
is less than 100 ms
• Accuracy: 0.5% + 0.5 V
• Activation time
• Accuracy: 0.5% + 0.05 A
• Activation time
10
rms
1
rms
; < 30 mV
2
2
: < 2ms
: < 2 ms
pp