9015 JEWELL / MODUTEC, 9015 Datasheet - Page 15

MULTIMETER DIGITAL HANDHELD, 3-1/2 DIGIT

9015

Manufacturer Part Number
9015
Description
MULTIMETER DIGITAL HANDHELD, 3-1/2 DIGIT
Manufacturer
JEWELL / MODUTEC
Datasheet

Specifications of 9015

Dmm Type
Handheld
Voltage Measuring Range Dc
1000
Voltage Measuring Range Ac
750
Current Measuring Range Dc
2mA To 10A
Current Measuring Range Ac
20mA To 10A
Lead Free Status / RoHS Status
na

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
9015
Manufacturer:
ST
0
Part Number:
9015
Manufacturer:
CJ/长电
Quantity:
20 000
Part Number:
90151-2114
Manufacturer:
MOLEX
Quantity:
12 000
Part Number:
90151-2116
Manufacturer:
MOLEX
Quantity:
42 144
Part Number:
90151-2116
Manufacturer:
MOLEX
Quantity:
35 000
Part Number:
901512104
Manufacturer:
Molex, LLC
Quantity:
201
Part Number:
901512106
Manufacturer:
Molex, LLC
Quantity:
184
7.3.2 Set the RANGE switch to a V
7.3.3 Connect the test probes to circuit being measured. The LCD will display
7.3.4 If the display indicates overrange, i.e. “1- - -”, disconnect the test probes
7.3.5 If the displayed value is less than “200” (decimal point not shown), a more
7.4 AC Voltage Measurement:
7.4.1 Connect the black test lead to the COM jack and the red test lead to the
7.4.2 Set the RANGE switch to a V
If the magnitude of the voltage to be measured is unknown, always start
by setting the meter to the highest range, and then to lower ranges,
Do not rotate the RANGE switch with the input applied to the meter.
If the input voltage is higher than 750VAC (CAT I), 600VAC (CAT II),
VOLT / OHM / BEEPER / DIODE / FREQ. “V
accurate reading may be obtained by setting the RANGE switch to a lower
switch to the next lower position. Reconnect the test probes to the circuit
voltage is unknown, set the RANGE switch to the highest V
If the input voltage is higher than the previously stated limits, do not
attempt to measure!
the DC voltage.
from the circuit and rotate the RANGE switch to the next higher position.
Reconnect the test probes to the circuit and observe the reading on the
LCD display. If the RANGE switch is already at the highest position
(i.e. 1000 VDC), the input voltage exceeds the measurement capability
of the meter and should not be measured.
range. Disconnect the probes from the circuit and rotate the RANGE
and observe the reading on the LCD display. If the RANGE switch is
already on the lowest position (i.e. 200mV DC), no greater measurement
resolution can be obtained.
voltage is unknown, set the RANGE switch to the highest V
If the input voltage is higher than the previously stated limits, do not
attempt to measure!
Use Caution when measuring voltages above 30V AC.
or 300VAC (CAT III), do not attempt to measure!
until a satisfactory reading is obtained.
WARNING!!!
~
position. If the magnitude of the
14
position. If the magnitude of the
kHz ” jack.
~
position.
position.