CPC5602CTR Clare, CPC5602CTR Datasheet - Page 7

MOSFET N-CH 350V 5MA SOT-223

CPC5602CTR

Manufacturer Part Number
CPC5602CTR
Description
MOSFET N-CH 350V 5MA SOT-223
Manufacturer
Clare
Type
Power MOSFETr
Datasheets

Specifications of CPC5602CTR

Fet Type
MOSFET N-Channel, Metal Oxide
Fet Feature
Depletion Mode
Rds On (max) @ Id, Vgs
14 Ohm @ 50mA, 350mV
Drain To Source Voltage (vdss)
350V
Current - Continuous Drain (id) @ 25° C
5mA
Input Capacitance (ciss) @ Vds
300pF @ 0V
Power - Max
2.5W
Mounting Type
Surface Mount
Package / Case
SOT-223 (3 leads + Tab), SC-73, TO-261
Number Of Elements
1
Polarity
N
Channel Mode
Depletion
Drain-source On-res
14Ohm
Drain-source On-volt
350V
Continuous Drain Current
5mA
Power Dissipation
2.5W
Output Power (max)
Not RequiredW
Frequency (max)
Not RequiredMHz
Noise Figure
Not RequireddB
Power Gain
Not RequireddB
Drain Efficiency
Not Required%
Operating Temp Range
-40C to 85C
Operating Temperature Classification
Industrial
Mounting
Surface Mount
Pin Count
3 +Tab
Package Type
SOT-223
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Gate Charge (qg) @ Vgs
-
Vgs(th) (max) @ Id
-
Lead Free Status / Rohs Status
Compliant
Other names
CLA298TR
CPC5602CTR

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CPC5602CTR
Manufacturer:
CPCLARE
Quantity:
18 210
Part Number:
CPC5602CTR
Manufacturer:
CPCLARE
Quantity:
453
Part Number:
CPC5602CTR
Manufacturer:
CPCLARE
Quantity:
20 000
Part Number:
CPC5602CTR
Quantity:
4 000
Command lines are typed to the modem from the termi-
nal when the modem is in the Idle or Command state.
The modem does not execute any of the commands in
a command line until after the command line is ended
by the end of line character <CR>. A command line is a
string of char-acters starting with the A and T characters
and ending with a special end of line character, <CR>.
Characters typed before the AT are ignored. Command
lines contain at most 40 characters after the AT, not
counting spaces. The modem does not execute any of
the commands in a command line that is too long.
To Echo command line characters, use the E1 com-
mand.
Typing mistakes can be aborted by using a special
Back-Space character, <BS>, after the initial A and T
characters have been entered.
A partial command line can be aborted by typing a Ctrl-
X character. The modem returns an OK result code and
ig-nores the partial AT command line.
Command lines may contain several commands one
after another. The Answer (A), Dial (D), and Go On-Line
(O) commands usually cause any following commands
in the command line to be ignored.
Command Line Execution
The characters in a command line are executed one at
a time. Any unexpected characters, except control char-
acters, stop command line execution and return an
ERROR result code. Unexpected characters include
numbers out-side the range of values accepted by the
command. All control characters in a command line
except Ctrl-X and the special characters such as <CR>
and <BS> are ignored.
The numerical argument of a command is assumed to
be 0 if it was not provided. For example, the commands
ATH<CR> and ATH0<CR> both hang up the telephone
line.
When the modem has executed a command line the
result code of the last command executed is returned to
the terminal. If the value to be written to a modem S-reg-
ister is outside the range of values accepted by the S-reg-
ister then its value is set to the nearest allowed value.
Leading zeros in numeric arguments, including S-regis-
ter numbers, are ignored. For example, ATS1=2 and
ATS01=2 both set S-register S1 to 2.
All numeric arguments, including S-register numbers,
Rev. 2
www.clare.com
are decimal (base 10).
AT Command Prefix
Each modem command line begins with the letters A
and T. The modem uses these characters to determine
the data rate and parity of data from the terminal.
A/Repeat Last Command
To repeat the commands in the last command line type
the letters A and / instead of A and T.
<CR>End Of Line Character
This character is typed to end a command line. The
value of the <CR> character is stored in S-register S3.
The de-fault is 13, the ASCII carriage return character.
When the <CR> character is entered, the modem exe-
cutes the commands in the command line.
Note: default values in the AT Command Tables are
denoted by bold face type.
CPC2400E
7

Related parts for CPC5602CTR