Specifications of NSH5-422UL-10M

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
3-4
3-4-1
External Connection
Diagram
Internal Memory or Host
(PLC) Memory Allocation
Function Switches
Function Switches
Overview
Function switches
Four NO contacts output to external devices
The NSH5 has ten function switches, and the status of these switches can be
sent to hard-wired outputs or to internal memory or host (PLC) memory.
The status of function switches F1, F2, F6, and F7 is output externally by
hard-wired outputs via the Special Cable. The status of the six remaining
switches (F3, F4, F5, F8, F9, and F10) are output to internal memory or host
(PLC) memory.
The status of function switches F1, F2, F6, and F7 are output externally by
hard-wired outputs via the Special Cable.
NSH5 function switches F3 to F5 and F8 to F10 can be allocated any bit
addresses in the internal memory or host (PLC) memory, and their ON/OFF
status can be monitored at the allocated address.
To specify the address in internal memory or host (PLC) memory that is to be
allocated to a function switch, first select PT - System Setting in CX-Designer
and then click the NS Handy Terminal Tab. In the Key Status Monitor
Address Field, click the appropriate Set Button, and specify the address that
is to be allocated.
F10
F1
F6
F7
F8
F9
NSH5
F2
F1
F2
F3
F4
F5
F6
F7
Software NO conditions
Hard-wired outputs
SW COM
F1
F2
F6
F7
Special Cable
PLC
PLC