NSH5-422UL-10M Omron, NSH5-422UL-10M Datasheet - Page 106

no-image

NSH5-422UL-10M

Manufacturer Part Number
NSH5-422UL-10M
Description
10m RS422 Cable For NSH5
Manufacturer
Omron
Datasheet

Specifications of NSH5-422UL-10M

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Local Inputs, Test Outputs,
Operation Chart
84
Recommended Enabling Circuits
IN0
IN1
IN2
IN3
IN4
IN5
IN6
IN7
IN8
IN9
IN10
T0
T1
T2
T3
Out0
Out1
EDM feedback
Mode indicator
Terminal
Reset switch
OUT0, OUT1
Emergency
name
Door switch
stop switch
Key switch
KM1, KM2
Enabling
IN4, IN5
IN6, IN7
IN8, IN9
contacts
IN0, IN1
IN2, IN3
switch
IN10
T3
Idle to Run
Test Pulse from Test Output
Test Pulse from Test Output
Test Pulse from Test Output
Test Pulse from Test Output
Test Pulse from Test Output
Test Pulse from Test Output
Test Pulse from Test Output
Test Pulse from Test Output
Test Pulse from Test Output
Test Pulse from Test Output
Test Pulse from Test Output
Test Pulse
Test Pulse
Test Pulse
Standard Output
Safety Pulse Test
Safety Pulse Test
350 ms min.
T
EDM
Door opened.
T
EDM
Mode
350 ms min.
T
EDM
: EDM feedback time
Run Mode
T
EDM
Emergency stop switch pressed.
T
EDM
T0
T1
T0
T1
T0
T1
T0
T1
T0
T1
T2
---
---
---
---
---
---
source
350 ms min.
Test
Enabling switch ON
T
EDM
E-Stop 2NC-1
E-Stop 2NC-2
Enable Switch 2NO-1
Enable Switch 2NO-2
Key Switch NC
Key Switch NO
Door Switch 2NC-1
Door Switch 2NC-2
Reset Switch 2NO-1
Reset Switch 2NO-2
EDM Feedback
---
---
---
Mode Indicator
KM1
KM2
Change from Run to Teaching mode
Terminal tag name
T
EDM
Enabling switch OFF
Door opened.
350 ms min.
T
EDM
Door closed.
T
Emergency stop switch
Enabling switch
Key switch for changing
modes
Door switch
Reset switch
Feedback for KM1, 2
---
---
---
Mode indicator
Safety output
Safety output
EDM
350 ms min.
Enabling switch ON
Application
T
Teaching Mode
EDM
Emergency stop switch pressed.
Appendix E
T
EDM
350 ms min.
T
EDM

Related parts for NSH5-422UL-10M