NSH5-422UL-10M Omron, NSH5-422UL-10M Datasheet - Page 111

no-image

NSH5-422UL-10M

Manufacturer Part Number
NSH5-422UL-10M
Description
10m RS422 Cable For NSH5
Manufacturer
Omron
Datasheet

Specifications of NSH5-422UL-10M

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Note For detailed information on the macro function, refer to the NS Series Macro Reference.
5. Transferring Project Data
6. Operation Check
Removable Box Application Examples
(6) Enter the following macro and the click the OK Button.
(7) After all settings have been entered, click the OK Button in the Edit Macro Dialog Box, in the When a
Connect the personal computer running CX-Designer to the NSH5 and transfer the project data (station
number screen data and other items) to the NSH5.
Perform the following steps to check if the project data settings have been correctly entered.
(1) Connect the NSH5 to Removable Box 2 and turn ON the Removable Box key switch. The NSH5 will
(2) Next, $SB1 is turned ON, and the “When a bit changed” macro is executed.
(3) Disconnect the NSH5 from Removable Box 2 and turn OFF the Removable Box's key switch. The
Bit Changed Dialog Box, and in the Project Property Dialog Box to close them.
start.
When the NSH5 starts, the initial screen (screen 0) will be displayed. The number 2 will be stored in
Station Status Monitor Address, $W1000.
The code “WRITECMEM(SERIALA:DM00200,$W1000,1);” writes 2 to PLC address DM00200.
The code “SHOWPAGE($W1000);” changes the PT display to the screen for station 2 (screen 2).
power to the NSH5 will be turned OFF.
WRITECMEM([SERIALA:DM00200],$W1000,1)
SHOWPAGE($W1000);
Station 1
Station Status Monitor Address $W1000: 0→2
NSH5
Screen 0→2
Station 2
PLC
DM00200 = 2
SHOWPAGE($W1000) changes the screen display to screen 2
Station 8
Writes the station number to DM00200.
(Entered before SHOWPAGE.)
Opens the screen with the same
number as the station number.
WRITECMEM([SERIALA:DM00200],$W1000,1);
writes "2" to DM00200
Appendix F