ACDC-620T Amprobe, ACDC-620T Datasheet - Page 7

DMM CLAMP-ON TRMS

ACDC-620T

Manufacturer Part Number
ACDC-620T
Description
DMM CLAMP-ON TRMS
Manufacturer
Amprobe
Type
Digital (DMM)r
Datasheet

Specifications of ACDC-620T

Includes
Battery, Case, Test Leads
Style
Clamp
Display Digits
4
Display Type
LCD, Bar Graph
Display Count
4000
Function
Voltage, Current, Resistance, Capacitance, Temperature
Functions, Extra
Continuity, Diode Test
Features
Auto Off, Hold, Min/Max/Ave, Sleep
Ranging
Auto/Manual
Response
True RMS
Frequency
45 Hz to 65 Hz
Maximum Ac Current
1 KA
True Rms
Yes
Voltage
400 V/100 V
Lead Free Status / RoHS Status
Contains lead / RoHS compliant by exemption
Other names
2730822
age than Installation Category lll.
Set the proper function and renge before attaching the metr to circuit. To avoid
damaging the meter disconnect the test leads from test points before changing
functions.
Read this operation manual completly before using the meter and follow all
safety instructions.
The meter is safety-certified in compliance with UL3111-1, C22.2 NO.1010.1-
insrtallation category (CAT) ll is an environment with smaller trasient overvolt-
CE requirement: Under the influence of R.F field according to standard, the
supplied test leads will pick up induced noice. To have better shielding tests
are required in order to conform to CE:
1. IEC 801-2: ESD (electro-static discharge) test.
2. IEC-801-3: RFI (Radio frequency Interference) test.
3. IEC 801-4: EFT(electro-fast transient) test.
4. EN 55011: EMI (electromagnetic interference) test.
Do not allow the temperature sensor to contact a surface which is energized
above 30 V RMS or 60V DC, such voltages pose a shock hazard.
92 and EN61010(IEC 1010-1, 1010-2031,IEC 1010-2-32) Instalation Category
ll 1000V or instalation Category lll 600V. In order to mantain its insulation
properties, please be sure to use ULListed Category ll 1000V or Category lll
600V probes.
Condition : 27 ~ 500MHz, signal intensity is 3 volts per meter.
5