ACD-330T Amprobe, ACD-330T Datasheet - Page 5

no-image

ACD-330T

Manufacturer Part Number
ACD-330T
Description
DMM CLAMP-ON W/BACKLIGHT
Manufacturer
Amprobe
Type
Digital (DMM)r
Datasheet

Specifications of ACD-330T

Includes
Battery, Case, Test Leads
Style
Clamp
Display Digits
4
Display Type
LCD, Bar Graph
Function
Voltage, Current, Resistance, Frequency
Functions, Extra
Continuity, Diode Test
Features
Auto Off, Backlight, Hold, Min/Max/Ave
Ranging
Auto/Manual
Response
True RMS
Lead Free Status / RoHS Status
Contains lead / RoHS compliant by exemption
Display Count
-
Other names
2730749
• This meter is for indoor use, altitude up to 2000m..
• Avoid working alone. Take precautions when working around moving parts.
• Use the meter only as specified in this manual. Otherwise, the protection provided by
• Never measure current while the test leads are inserted into the input terminals.
• Inspect the leads for damaged insulation or exposed metal. Check test leads continuity.
• Disconnect the power and discharge all high-voltage capacitors before testing in the
• When making measurements, keep your fingers behind the finger guards, on the probe.
• Set the proper function and range before attaching the meter to circuit. To avoid
• The meter is safety-certified in compliance with UL311-1, C22.2 NO.1010.1-92 and
• Installation Category (CAT) II is an environment with smaller transient over voltage than
To ensure that youuse the meter safety, follow the safety guidelines listed below.
• Use extreme caution what working around bare conductors or him bars. Accidental
• Do use the meter if it looks damaged.
• Use caution when working above 60VDC or 30VAC RMS, Such voltages pose a
• Read this operation manual completely before using the meter and follow all
• CE requirement: Under the influence of R.F. field according to standard, the supplied test
contact with the conductor could result in electric shock.
the meter may be impared.
Replace damaged leads.
damaging the meter disconnect the test leads from test points before changing functions.
safety instructions.
EN61010 (IEC1010-1, IEC 1010-2-031, IEC 1010-2-032). Installation Category II 1000V
or Installation Category III 600V. In order to maintain its insulation properties, please be
Installation Category III.
be used. The following tests are required in order to conform to CE:
resistance, continuity, and diode function.
shock hazard.
sure to use with ULListed Category II 1000Vor Category III 600V p r o b e s .
leads will pick up induced noise. To have better shielding effect, a short test lead should
SAFETY INFORMATION
1. IEC 801-2:ESD (electro static discharge) test.
2. IEC 801-3:RFI (Radio Frequency Interference) test.
Condition: 27 ˜ ˜ 5 0 0 M H
3. IEC 801-4:EFT(electro fast transient) test.
4. EN 55011: EMI (electro magnetic interference) test.
SAFETY INFORMATION
Z
, signal intensity is 3 volts per meter.
1