ACD-330T Amprobe, ACD-330T Datasheet - Page 39

no-image

ACD-330T

Manufacturer Part Number
ACD-330T
Description
DMM CLAMP-ON W/BACKLIGHT
Manufacturer
Amprobe
Type
Digital (DMM)r
Datasheet

Specifications of ACD-330T

Includes
Battery, Case, Test Leads
Style
Clamp
Display Digits
4
Display Type
LCD, Bar Graph
Function
Voltage, Current, Resistance, Frequency
Functions, Extra
Continuity, Diode Test
Features
Auto Off, Backlight, Hold, Min/Max/Ave
Ranging
Auto/Manual
Response
True RMS
Lead Free Status / RoHS Status
Contains lead / RoHS compliant by exemption
Display Count
-
Other names
2730749
Table 3. illustrates the relationship between AC and DC components for common
waveforms, and compares readings for TRUE RMS meters and average-respond-
ing meters. For example, consider the first waveform, a 141.4AV (zero-to-peak)
sine wave. Both this Clamp-on meter and RMS-calibrated average-responding
meters display the correct RMS reading of 100.0V(the DC component equals 0).
AC component (100.0V). The average-responding meter measures 111.1V, which
amounts to an 11 %error.
The conversion factors in Table 3 show the differences between average sensing
instrument measurements and true RMS instrument
However, consider the 200V(peak-to-peak) square wave, both types of meter cor-
rectly measure the DC component (0V). The clamp meter correctly measures the
WA VEFORM COMPARISON
35