ACD-330T Amprobe, ACD-330T Datasheet - Page 11

no-image

ACD-330T

Manufacturer Part Number
ACD-330T
Description
DMM CLAMP-ON W/BACKLIGHT
Manufacturer
Amprobe
Type
Digital (DMM)r
Datasheet

Specifications of ACD-330T

Includes
Battery, Case, Test Leads
Style
Clamp
Display Digits
4
Display Type
LCD, Bar Graph
Function
Voltage, Current, Resistance, Frequency
Functions, Extra
Continuity, Diode Test
Features
Auto Off, Backlight, Hold, Min/Max/Ave
Ranging
Auto/Manual
Response
True RMS
Lead Free Status / RoHS Status
Contains lead / RoHS compliant by exemption
Display Count
-
Other names
2730749
WARNING
To avoid damaging the meter, do not exceed input limits shown below in Table 1:
The meter has two input terminals ( Figure 5) that are protected against overloads to the
2) Volts, Ohms, Diode, measurements.
limits shown in the specifications.
1) Common terminal for all measurements (except current).
AC 400 ~ 600V (CAT III)
AC 400 ~ 1000V(CAT II)
DC 400 ~1000V(CAT II)
DC 400 ~600V (CAT III)
AC 400 ~ 1000A
OHM ( )
DIODE (
ROTARY SWITCH
INPUT TERMINAL
FUNCTION
)
)
)
)
Table 1. Input limit Specifications
1
Figure 5. Input Terminal
V- -
V- -
TERMINAL
Clamp Jaw
INPUT
& COM
& COM
7
2
1000VAC/ 1000VDC
INPUTLIMIT
1000ARMS
600VRMS
CAT III
CAT II
600V