FLUKE-289/FVF Fluke Electronics, FLUKE-289/FVF Datasheet - Page 81

COMBO KIT DMM & ACCESSORY

FLUKE-289/FVF

Manufacturer Part Number
FLUKE-289/FVF
Description
COMBO KIT DMM & ACCESSORY
Manufacturer
Fluke Electronics
Series
FlukeView® Forms, 28xr
Type
Digital (DMM)r
Datasheet

Specifications of FLUKE-289/FVF

Includes
Battery, Case, Clips, Software, Temperature Probe, Test Leads
Style
Handheld
Display Digits
4.5
Display Type
LCD, Bar Graph
Display Count
50000
Function
Voltage, Current, Resistance, Capacitance, Temperature, Frequency
Functions, Extra
Continuity, dB
Features
Data Logging, Hold, Memory, Min/Max/Ave
Ranging
Auto/Manual
Response
True RMS
Lead Free Status / RoHS Status
Not applicable / RoHS non-compliant
Other names
289/FVF
614-1063
DC Current Specifications
DC A
DC mA
DC A
[1]
[2]
[3]
[4]
[5]
[6]
Function
[2]
AC+DC ranges are specified from 2 % to 140 % of range.
20 A for 30 seconds on, 10 minutes off. >10 A not specified.
Add 20 counts in dual display ac over dc, dc over ac or ac+dc.
400 mA continuous; 550 mA for 2 minutes on, 1 minute off.
Verified by design and type tests.
Temperature coefficient: 0.1 X (specified accuracy)/ C (<18 C or > 28 C)
[4]
[4]
500 A
5000 A
50 mA
400 mA
5 A
10 A
Range
0.01 A
0.1 A
0.001 mA
0.01 mA
0.0001 A
0.001 A
Resolution
0.05 % + 10
0.075 % + 20
0.075 % + 2
0.15 % + 2
0.3 % + 10
0.3 % + 2
DC
[1][3]
[6]
20 to 45 Hz
1.5 % + 20
1.5 % + 10
1 % + 20
1 % + 20
1 % + 5
1 % + 5
AC over DC, DC over AC, AC + DC
45 Hz to 1 kHz
Accuracy
0.6 % + 20
0.6 % + 20
0.8 % + 20
0.8 % + 10
0.6 % + 5
0.6 % + 5
1 to 20 kHz
0.6 % + 20
0.6 % + 10
0.6 % + 20
1.5 % + 10
3 % + 40
3 % + 10
Detailed Specifications
[5]
[5]
[1]
20 to 100 kHz
Not Spec’d
Not Spec’d
5 % + 40
5 % + 40
5 % + 40
5 % + 40
71
[5]