FLUKE-289/FVF Fluke Electronics, FLUKE-289/FVF Datasheet - Page 31

COMBO KIT DMM & ACCESSORY

FLUKE-289/FVF

Manufacturer Part Number
FLUKE-289/FVF
Description
COMBO KIT DMM & ACCESSORY
Manufacturer
Fluke Electronics
Series
FlukeView® Forms, 28xr
Type
Digital (DMM)r
Datasheet

Specifications of FLUKE-289/FVF

Includes
Battery, Case, Clips, Software, Temperature Probe, Test Leads
Style
Handheld
Display Digits
4.5
Display Type
LCD, Bar Graph
Display Count
50000
Function
Voltage, Current, Resistance, Capacitance, Temperature, Frequency
Functions, Extra
Continuity, dB
Features
Data Logging, Hold, Memory, Min/Max/Ave
Ranging
Auto/Manual
Response
True RMS
Lead Free Status / RoHS Status
Not applicable / RoHS non-compliant
Other names
289/FVF
614-1063
Making Relative Measurements
The Meter displays calculated values that are based on a stored
value when set to relative and relative percent mode. Figure 9
shows the functions for which the two relative modes are
available. In addition, the two relative modes are available in
frequency, duty cycle, pulse width, crest factor, and dB.
To activate the relative or relative percent modes while in one of
the functions shown in Figure 9, press the softkey labeled Menu.
Move the menu selector to the menu item labeled REL. Next,
press either the softkey labeled REL or REL%. The
measurement value at the time that either Rel or Rel % is
enabled, is stored as the reference value and displayed in the
Figure 9. Relative Mode Functions
est29.eps
secondary display. The present or “Live” measurement moves to
the secondary display and the primary display indicates the
difference between the present measurement and the reference
value in measurement units for REL and as a percentage for
REL %.
When relative percent is enabled, the bar graph is a zero-
centered bar graph that indicates the percentage difference. The
bar graph’s range is limited to 10 %, but the display goes to
the reference value is 0, the Meter displays OL.
With the exception of dB measurements, ranging is set to
manual and can not be changed. Both auto and manual ranging
is possible when making relative dB measurements.
When relative is enabled during dBm or dBV measurements, the
displayed units change to dB.
In relative or relative percent mode, the softkey label for F3
indicates REL or REL%, depending on which of the two modes
is not presently selected. The F3 button acts as a toggle,
switching the Meter between the two modes. Moving the rotary
switch between V and mV while in relative dBm or dBv mode
does not disable the dB measurement. This allows continuous
measurements over a wide range of input voltage.
999.9 %. At 1000 % or more, the display indicates OL. When
Making Relative Measurements
21