FLUKE-289/FVF Fluke Electronics, FLUKE-289/FVF Datasheet - Page 33

COMBO KIT DMM & ACCESSORY

FLUKE-289/FVF

Manufacturer Part Number
FLUKE-289/FVF
Description
COMBO KIT DMM & ACCESSORY
Manufacturer
Fluke Electronics
Series
FlukeView® Forms, 28xr
Type
Digital (DMM)r
Datasheet

Specifications of FLUKE-289/FVF

Includes
Battery, Case, Clips, Software, Temperature Probe, Test Leads
Style
Handheld
Display Digits
4.5
Display Type
LCD, Bar Graph
Display Count
50000
Function
Voltage, Current, Resistance, Capacitance, Temperature, Frequency
Functions, Extra
Continuity, dB
Features
Data Logging, Hold, Memory, Min/Max/Ave
Ranging
Auto/Manual
Response
True RMS
Lead Free Status / RoHS Status
Not applicable / RoHS non-compliant
Other names
289/FVF
614-1063
Using LoZ for Voltage Measurements (Model
289 only)
To eliminate ghost voltages, the Meter’s LoZ function presents a
low impedance across the leads to obtain a more accurate
measurement.
To make a LoZ measurement, set the rotary switch to L. The
Meter displays the ac voltage in the primary display and the dc
voltage in the secondary display. During LoZ measurements, the
Meter’s range is set to 1000 volts in the manual ranging mode.
In LoZ, both R and M are disabled. There are no additional
modes for this function and the softkey labeled Menu is therefore
disabled as well.
Making dB Measurements
The Meter is capable of displaying voltage as a dB value, either
relative to 1 milliwatt (dBm), a reference voltage of 1 volt (dBV)
or a user-selectable reference value. See the “Setting a Custom
dBm Reference” section later in this manual.
Do not use the LoZ mode to measure voltages in
circuits that could be damaged by this mode’s low
impedance ( 3 k ).
W Caution
To set the Meter to display values in dBm, set the rotary switch
to V or T and press the softkey labeled Menu. Move the menu
selector to the menu item labeled dBm. Press the softkey
labeled dBm. The dBm, Hz menu selection replaces the
secondary display (123.45 VAC in Figure 11) with the frequency
measurement. All voltage measurements are displayed as a
dBm value, as shown in Figure 11.
A dBm measurement must use a reference impedance
(resistance) to calculate a dB value based on 1 milliwatt. When
set to 600
during a dBm measurement. When set to something other than
600 , the reference impedance is displayed just above the
softkey labels.
0
Menu
8:10pm
(default), the reference impedance is not displayed
100
41.83
Figure 11. dBm Display
Save
200
123.45
300
1000
Ref
Making Measurements
400
Reference
dBm
VAC
Auto Range
06/13/07
Setup
500 VAC
est08.eps
23