MTCMR-C1-GP-N3 Multi-Tech Systems, MTCMR-C1-GP-N3 Datasheet - Page 59

no-image

MTCMR-C1-GP-N3

Manufacturer Part Number
MTCMR-C1-GP-N3
Description
MODEM CELLULAR DUAL CDMA
Manufacturer
Multi-Tech Systems
Series
MultiModem® iCellr
Datasheets

Specifications of MTCMR-C1-GP-N3

Function
Transceiver, CDMA, Modem
Modulation Or Protocol
CDMA2000
Frequency
800MHz, 1.9GHz, 1575.42MHz
Applications
Verizon™ Networks (USA)
Interface
RS-232, USB
Sensitivity
-161dB
Data Rate - Maximum
153.6kbps
Voltage - Supply
9 V ~ 32 V, USB
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
881-1097
Mobile Directory Number +WMDN
Description:
Syntax:
Note:
Value:
Primary CDMA Channels +WPCC
Description:
Syntax:
Values:
Secondary CDMA Channels +WSCC
Description:
Syntax:
Values:
Multi-Tech Systems, Inc. CDMA C1 AT Commands Reference Guide (PN S000478C)
This command is used to enter a new mobile directory number. Valid numbers are between 10
and 15 digits in length. For support of Wireless Number Portability in all non-RUIM software
versions, changes to the MDN will update the IMSI_M portion (least significant 10 digits) of the
IMSI. Changes to the MDN will also automatically update the Access Overload Class values
unless specifically modified using the +WAOC command. The new IMSI_M and Access Overload
Class values will not be visible in the WIMI and WAOC commands until after the changes are
committed with the WCMT command.
Command syntax: AT+WMDN=<number>
Verizon based wireless modems propagate the MDN to SIP NAI, MIP NAI, tethered NAI, and
PPP user ID when the MDN is committed using the AT+WCMT=1 command.
<number>
This command is used to set the primary CDMA channels for 800Mhz CDMA operation only.
Values entered must be valid CDMA 800Mhz Channel numbers. If an invalid channel number is
entered, the number will be automatically set to the appropriate default value at restart.
Command syntax: AT+WPCC=<channel a number>,<channel b number>
<channel a number>
<channel b number> Value range: 0 – 2047
This command is used to set the secondary CDMA channels for 800Mhz CDMA operation only.
Values entered must be valid CDMA 800Mhz Channel numbers. If an invalid channel number is
entered, the number will be automatically set to the appropriate default value at restart.
Command syntax: AT+WSCC=<channel a number>,<channel b number>
<channel a number> Value range: 0 – 2047
<channel b number> Value range: 0 – 2047
Command
AT+WMDN?
Note: Get current mobile directory number
AT+WMDN=8585551212
Note: Set mobile directory number to 8585551212
Command
AT+WPCC?
Note: Get current primary CDMA channels
AT+WPCC=211,432
Note: Set the primary CDMA channels
AT+WPCC=?
Command
AT+WSCC?
Note: Get current secondary CDMA channels
AT+WSCC=511,632
Note: Set the secondary CDMA channels
AT+WSCC=?
Can be up to 15 digits
Value range: 0 – 2047
Possible Responses
+WPCC: 283,384
OK
OK
+WPCC: (0-2047),(0-2047
Possible responses
+WSCC: 691,777
OK
OK
+WSCC: (0-2047),(0-2047
Chapter 11 – Provisioning Control Commands
Possible Responses
+WMDN: 8581111111
OK
OK
59