Register 0x6 allows the user to enable or disable any of the alarm flags that are not required. If disabled, that particular alarm no longer
flags on the appropriate open-drain pin; however, the alarm status is still available in both of the alarm status registers (Address 0x43 and
Address 0x44).
Table 22. Alarm Setup Register
Address
0x6
Default
0x0000
Data Bits, MSB First
Bit
15
14
13
12
11
10
9
8
7
6
5:0
Name
Latched
TMPALM
Disable
TMPALM
Latched
OSALM
Disable
OSALM
Latched
DUTALM
Disable
DUTALM
Latched
CLALM
Disable
CLALM
Latched
GRDALM
Disable
GRDALM
Unused
Function
Set this latched bit high to program the open-drain TMPALM alarm pin as a latched output;
leave low for an unlatched alarm pin (default).
Set this bit high to disable the open-drain TMPALM alarm pin; leave low to leave enabled (default).
Set this latched bit high to program the OSALM as a latched alarm on the open-drain KELALM
pin; leave low for an unlatched alarm pin (default).
Set this bit high to disable the OSALM alarm function flagging the open-drain KELALM pin;
leave low to remain enabled (default). The disable GRDALM, DUTALM, and OSALM alarm
functions share one open-drain KELALM alarm pin. These bits allow users to choose if they wish
to have all or selected information flagged to the alarm pin.
Set this latched bit high to program the DUTALM as a latched alarm on the open-drain KELALM
pin; leave low for an unlatched alarm pin (default).
Set this bit high to disable the DUTALM alarm function flagging the open-drain KELALM pin.
Leave low to leave enabled (default). The disable GRDALM, DUTALM, and OSALM alarm
functions share one open drain KELALM alarm pin. These bits allow users to choose if they wish
to have all or any information flagged to the alarm pin. The DUTGND pin has a 50 μA pull-up to
allow for detection of an error in the DUTGND path. Setting this bit high also disables the 50 μA
pull-up.
Set this latched bit high to program the open-drain CLALM clamp alarm pin as a latched
output; leave low for an unlatched alarm pin (default).
Set this bit high to disable the open drain CLALM alarm pin; leave low to leave enabled (default).
Set this latched bit high to program the GRDALM as a latched alarm on the open-drain KELALM
pin; leave low for an unlatched alarm pin (default).
Set this bit high to disable the GRDALM alarm function flagging the open-drain KELALM pin;
leave low to leave enabled (default). The disable GRDALM, DUTALM and OSALM alarm functions
share one open-drain KELALM alarm pin. These bits allow users to choose if they wish to have
all or any information flagged to the KELALM alarm pin.
Set to 0.
Rev. C | Page 49 of 60