ADUC7036CCPZ-RL Analog Devices Inc, ADUC7036CCPZ-RL Datasheet - Page 114

no-image

ADUC7036CCPZ-RL

Manufacturer Part Number
ADUC7036CCPZ-RL
Description
Flash 96k ARM7 Dual 16-Bit ADC LIN I.C.
Manufacturer
Analog Devices Inc
Series
MicroConverter® ADuC7xxxr
Datasheet

Specifications of ADUC7036CCPZ-RL

Core Processor
ARM7
Core Size
16/32-Bit
Speed
20.48MHz
Connectivity
LIN, SPI, UART/USART
Peripherals
PSM, Temp Sensor, WDT
Number Of I /o
9
Program Memory Size
96KB (96K x 8)
Program Memory Type
FLASH
Eeprom Size
-
Ram Size
6K x 8
Voltage - Supply (vcc/vdd)
3.5 V ~ 18 V
Data Converters
A/D 2x16b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 115°C
Package / Case
48-VFQFN Exposed Pad, CSP
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
ADuC7036
Serial Test Interface Control Register
Name: STICON
Address: 0xFFFF0884
Default Value: 0x0000
Access: Read/write access, write protected by two key registers (STIKEY0 and STIKEY1). A write access to STICON is completed
correctly only if the following triple write sequence is followed:
1.
2.
3.
Function: The STI Control MMR is an 16-bit register that configures the mode of operation of the serial test interface.
Note that the GPIO_13 must be configured for STI operation in GP2CON for STI communications.
Table 91. STICON MMR Bit Designations
Bit
15 to 9
8 to 5
4 to 2
1
0
STIKEY0 MMR is written with 0x0007.
STICON is written.
The sequence is completed by writing 0x00B9 to STIKEY1.
Description
Reserved. These bits are reserved for future use and should be written as 0 by user code.
State bits, read only. If the interface is in the middle of a transmission, these bits are not 0.
Number of bytes to transmit. These bits select the number of bytes to be transmitted. User code must subsequently
write the bytes to be transmitted into the STIDAT0, STIDAT1, and STIDAT2 MMRs.
000 = 1-byte transmission.
001 = 2-byte transmission.
010 = 3-byte transmission.
011 = 4-byte transmission.
100 = 5-byte transmission.
101 = 6-byte transmission.
Reset serial test interface.
1 = resets the serial test interface. A subsequent read of STICON returns all 0s.
0 = operates in normal mode (default).
Serial test interface enable. This bit is set by user code.
1 = enables the serial test interface.
0 = disables the serial test interface.
Rev. C | Page 114 of 132