HSDL-3612-038 Lite-On Electronics, HSDL-3612-038 Datasheet - Page 14

Infrared Transceivers IR Transceiver

HSDL-3612-038

Manufacturer Part Number
HSDL-3612-038
Description
Infrared Transceivers IR Transceiver
Manufacturer
Lite-On Electronics
Type
TX/RXr
Datasheet

Specifications of HSDL-3612-038

Wavelength
875 nm, 880 nm
Continual Data Transmission
115.2 Kbit/s
Transmission Distance
1.5 m
Radiant Intensity
120 mW/sr
Half Intensity Angle Degrees
30 deg to 60 deg
Pulse Width
4 us, 1.6 us
Maximum Rise Time
40 ns, 25 ns
Maximum Fall Time
40 ns, 25 ns
Led Supply Voltage
- 0.5 V to 7 V
Maximum Forward Current
165 mA
Operating Voltage
2.7 V to 5.25 V
Maximum Operating Temperature
+ 70 C
Minimum Operating Temperature
- 20 C
Dimensions
12.2 mm x 5.1 mm x 4 mm
Data Rate
115.2Kbps
Peak Wavelength
875/880nm
Angle Of Half Sensitivity
60/30°
Communication Distance
150
Package Type
Ultra Small Profile
Fall Time
40/25ns
Rise Time
40/25ns
Operating Supply Voltage (typ)
3.3/5V
Operating Supply Voltage (min)
2.7V
Operating Supply Voltage (max)
5.25V
Mounting
Surface Mount
Pin Count
11
Operating Temp Range
-20C to 70C
Operating Temperature Classification
Commercial
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
14
Recommended Reflow Profile
Heat Up
Solder Paste Dry
Solder Reflow
Cool Down
The reflow profile is a straight-line representation of a
nominal temperature profile for a convective reflow sol-
der process. The temperature profile is divided into four
process zones, each with different ∆T/∆time tempera-
ture change rates. The ∆T/∆time rates are detailed in
the above table. The temperatures are measured at the
component to printed circuit board connections.
In process zone P1, the PC board and HSDL-3612 cas-
tellation pins are heated to a temperature of 160°C to
activate the flux in the solder paste. The temperature
ramp up rate, R1, is limited to 4°C per second to allow
for even heating of both the PC board and HSDL-3612
castellations.
Process zone P2 should be of sufficient time duration
(60 to 120 seconds) to dry the solder paste. The tem-
perature is raised to a level just below the liquidus point
of the solder, usually 200°C (392°F).
Process zone P3 is the solder reflow zone. In zone P3,
the temperature is quickly raised above the liquidus
point of solder to 255°C (491°F) for optimum results. The
dwell time above the liquidus point of solder should
be between 20 and 60 seconds. It usually takes about
Process Zone
230
200
183
170
150
125
100
50
25
0
HEAT
R1
UP
P1
50
SOLDER PASTE DRY
R2
Symbol
P1, R1
P2, R2
P3, R3
P3, R4
P4, R5
P2
100
t-TIME (SECONDS)
150
R3
MAX. 245 C
DT
25°C to 160°C
160°C to 200°C
200°C to 255°C
(260°C at 10 seconds max.)
255°C to 200°C
200°C to 25°C
REFLOW
SOLDER
90 sec.
ABOVE
MAX.
183 C
P3
200
R4
20 seconds to assure proper coalescing of the solder
balls into liquid solder and the formation of good solder
connections. Beyond a dwell time of 60 seconds, the
intermetallic growth within the solder connections be-
comes excessive, resulting in the formation of weak and
unreliable connections. The temperature is then rapidly
reduced to a point below the solidus temperature of the
solder, usually 200°C (392°F), to allow the solder within
the connections to freeze solid.
Process zone P4 is the cool down after solder freeze.
The cool down rate, R5, from the liquidus point of the
solder to 25°C (77°F) should not exceed 6°C per second
maximum. This limitation is necessary to allow the PC
board and HSDL-3612 castellations to change dimen-
sions evenly, putting minimal stresses on the HSDL-
3612 transceiver.
DOWN
COOL
P4
R5
250
300
Maximum DT/Dtime
4°C/s
0.5°C/s
4°C/s
-6°C/s
-6°C/s

Related parts for HSDL-3612-038