T1611100 Red Lion Controls, T1611100 Datasheet - Page 9

PID TEMPERATURE CONTROLLER, 3RELAYS

T1611100

Manufacturer Part Number
T1611100
Description
PID TEMPERATURE CONTROLLER, 3RELAYS
Manufacturer
Red Lion Controls
Type
Temperaturer
Datasheets

Specifications of T1611100

Thermocouple Type
T, E, J, K, R, S, B, N, C, Linear MV
Operating Temperature Max
50°C
Operating Temperature Min
0°C
Output Voltage Max
250VAC
Output Voltage Min
30VDC
Accuracy
0.3%
Approval
RoHS Compliant
Brand/series
T16 Series
Contact Form
SPST
Dimensions
49.5mmW×49.5mmH×115.3mmD
Enclosure Rating
IP65
Input Type
RTD/Thermocouple
Ip Rating
IP65
Memory
EEPROM
Mounting Type
Panel
Output Type
Relay
Power, Rating
8 VA
Primary Type
Controller
Special Features
EEPROM
Standards
cURus, CE
Termination
Screw
Voltage, Supply
85 to 250 VAC
Lead Free Status / Rohs Status
RoHS Compliant part
HIDDEN LOOP
Hidden Loop. The Temperature/Process Value is shown in the top display. The
bottom display alternates between the parameter and its selection/value. # or
$ is pressed to change the selection/value for the shown parameter. The new
selection/value is activated after " is pressed. When ! is pressed, the
controller returns to the Display Loop and stores changed selection/values to
permanent memory. Hidden Loop parameters may be locked out in Lockout
Module 3-LC. Some parameters are model and programming dependent.
"
setpoint 2. In the Display Loop, there is no annunciator indicating the selected
Setpoint, however, the selected Setpoint value is displayed and activated.
"
Code will appear here. By entering the proper Code, access to the Hidden Loop
is permitted. With the factory setting of 0, Access Code will not appear in the
Hidden Loop. A universal code of 111 can be entered to gain access,
independent of the programmed code number.
6.0 P
To enter Hidden Loop, press " for 3 seconds.
When " is pressed and held for three seconds, the controller advances to the
SPSL
The SPSL function allows the operator to switch from or to, setpoint 1 and
CodE
If the Access Code is set from 1 to 125, in Lockout Module '%(), Access
Note: Parameters shown bold are the only parameters visible in the Hidden Loop with Factory Settings. Setpoint and Output Power are
Parameter availability is model and programming dependent.
factory set for the Display Loop. The remaining parameters can be selected for the Hidden Loop within Module 3.
SP1
#
#
0
ROGRAMMING
SP1
1
to
SETPOINT SELECT
125
or
ACCESS CODE
SP2
: H
HIDDEN LOOP
IDDEN
9
"
overshoot on startup or after setpoint changes, by ramping the setpoint at a
controlled rate. R annunciator flashes while ramping. With the T16, the ramp rate
is always in tenths of degrees per minute, regardless of the resolution chosen for
the process display. With the P16, the ramp rate is in least-significant (display
units) digits per minute. A value of 0.0 or 0 disables setpoint ramping. Once the
ramping setpoint reaches the target setpoint, the setpoint ramp rate disengages
until the setpoint is changed again. If the ramp value is changed during ramping,
the new ramp rate takes effect. If the setpoint is ramping prior to starting Auto-
Tune, the ramping is suspended during Auto-Tune and then resumed afterward.
Deviation and band alarms are relative to the target setpoint, not the ramping
setpoint. A slow process may not track the programmed setpoint rate. At power
up, the ramping setpoint is initialized at the ambient temperature/process value.
"
determined by the controller. In Manual/User USEr Mode, the percentage of
Output Power is adjusted manually while in the Display Loop. The Control
Mode can also be transferred through the F1 Key or User Input. For more
information, see Control Mode Explanations.
SPrP
The setpoint ramp rate can reduce sudden shock to the process and reduce
trnF
In Automatic Mode, the percentage of Output Power is automatically
L
Auto
OOP
0. 0
#
#
CONTROL MODE TRANSFER
0. 0
Auto USEr
SETPOINT RAMP RATE
to
999. 9