T1611100 Red Lion Controls, T1611100 Datasheet - Page 5

PID TEMPERATURE CONTROLLER, 3RELAYS

T1611100

Manufacturer Part Number
T1611100
Description
PID TEMPERATURE CONTROLLER, 3RELAYS
Manufacturer
Red Lion Controls
Type
Temperaturer
Datasheets

Specifications of T1611100

Thermocouple Type
T, E, J, K, R, S, B, N, C, Linear MV
Operating Temperature Max
50°C
Operating Temperature Min
0°C
Output Voltage Max
250VAC
Output Voltage Min
30VDC
Accuracy
0.3%
Approval
RoHS Compliant
Brand/series
T16 Series
Contact Form
SPST
Dimensions
49.5mmW×49.5mmH×115.3mmD
Enclosure Rating
IP65
Input Type
RTD/Thermocouple
Ip Rating
IP65
Memory
EEPROM
Mounting Type
Panel
Output Type
Relay
Power, Rating
8 VA
Primary Type
Controller
Special Features
EEPROM
Standards
cURus, CE
Termination
Screw
Voltage, Supply
85 to 250 VAC
Lead Free Status / Rohs Status
RoHS Compliant part
same range selected in programming Module 2-OP. The default jumper
setting is for 20 mA. The default setting in Module 2-OP is 4-20
mA. To access the jumpers, insert a flat-blade screwdriver
between the front panel and the side case slot. This
should disengage the top and bottom front panel
latches from the case grooves. Pull the
front panel assembly with the controller
boards out of the case. The jumpers
are located inside the controller
on the left board along the
back top section.
use to provide a watertight seal in steel panels with a minimum thickness of
0.09", or aluminum panels with a
minimum thickness of 0.12". The
controllers are designed to be
mounted into an enclosed panel.
The bezel assembly must be in
place during installation of
the controller.
Multiple Controller Stacking
in applications that do not require protection to NEMA 4X. Controllers can be
stacked either horizontally or vertically. For vertical stacking, install the panel
latch with the screws to the sides of the controller. For horizontal stacking, the
panel latch screws should be at the top and bottom of the controller. The
minimum spacing from centerline to centerline of controllers is 1.96" (49.8
mm). This spacing is the same for vertical or
horizontal stacking.
Note: When stacking
1.0 S
2.0 I
To insure proper operation, the Analog Output jumpers must be set to the
The T16 and P16 controllers meet NEMA 4X/IP65 requirements for indoor
The controller is designed to allow for close spacing of multiple controllers
controllers, provide
adequate panel
ventilation to ensure
that the maximum
operating temperature
range is not exceeded.
NSTALLING THE
ETTING THE
J
UMPERS
C
ONTROLLER
VIEW FROM TOP OF UNIT
5
Instructions:
1. Prepare the panel cutout to the proper dimensions.
2. Remove the panel latch from the controller. Discard the cardboard sleeve.
3. Carefully remove the center section of the panel gasket and discard. Slide the
4. Insert the controller into the panel cutout. While holding the controller in
5. To achieve a proper seal, tighten the panel latch
Note: The installation location of the controller is
panel gasket over the rear of the controller, seating it against the lip at the
front of the case.
place, push the panel latch over the rear of the controller, engaging the tabs
of the panel latch in the farthest forward slot possible.
screws evenly until the controller is snug in the
panel, torquing the screws to approximately 7 in-
lb (79 N-cm). Overtightening can result in
distortion of the controller, and reduce the
effectiveness of the seal.
important. Be sure to keep it away from heat
sources (ovens, furnaces, etc.) and away from
direct contact with caustic vapors, oils, steam, or
any other process by-products in which exposure
may affect proper operation.
(A
NALOG
O
UTPUT
M
ODELS
O
NLY
)

Related parts for T1611100