72
Sample Program
First Cycle
Flag
First Cycle
Flag
Continued
Continued
W300.00
W300.00
A200.11
A200.11
Receiving Data from the Digital Multimeter
2000.00
2007.07
2007.08
2007.09
2005.00
MOV(021)
MOV(021)
MOV(021)
MOV(021)
MOV(021)
MOV(021)
MOV(021)
ASL(025)
FAL(006)
2000.00
#0003
#0001
#0001
#0000
#0003
#0000
#000A
RSET
W511
W410
W411
W412
W040
W041
W042
W043
3
0
Turns OFF the Send Interface Message Request Bit if the message was sent
properly and the Interface Message Send Completed Flag was turned ON.
Refreshes the command control bits in W511.
Generates a non-fatal error (FAL number 3) if an error occurred.
Stores data that will be written in buffer memory.
Transmitting device address: 0003 Hex
Number of receiving device addresses: 0001 Hex
Receiving device address: 0001 Hex
Sets parameters for IOWR(223).
Unit number of destination device: 0000 Hex
Number of words to transfer: 0003 Hex
Sets parameters for IORD(222).
Unit number of source device: 0000 Hex
Number of words to transfer: 000A Hex
Appendix A