C500BC031 Omron, C500BC031 Datasheet - Page 18

no-image

C500BC031

Manufacturer Part Number
C500BC031
Description
BACKPLANE
Manufacturer
Omron
Datasheet

Specifications of C500BC031

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
System Configuration
1-1
*
RS-422: RS-422 cable/RS-232C: RS-232C cable
**
*** Reading or writing words in the portion of the EM area expanded by the C200HX/C200HG/C200HE is not possible.
**** C200H Rack-mounting Host Link Units cannot be used with C200HX/HG/HE “-Z-type” PCs or CS1-series PCs.
1-2
2
C200H-LK101-PV1***
C200H-LK201-V1***
C200H-LK202-V1***
3G2A5-LK101-PEV1
C500-LK103-P**
3G2A5-LK101-EV1
3G2A5-LK201-EV1
C500-LK103**
C500-LK203**
3G2A6-LK101-PEV1
3G2A6-LK101-EV1
3G2A6-LK201-EV1
3G2A6-LK202-EV1
APF: All-plastic optical fiber cable/PCF: Plastic-clad optical fiber cable/H-PCF: Hard-clad plastic optical fiber cable/
The C500-LK103(-P) and C500-LK203 can be used with the C500 PC only when the 3G2C3-CPU11-EV1 is used.
Host Link Unit
Applicable Units
System Configuration
Rack-mounting
Rack-mounting
Rack-mounting
Rack-mounting
Rack-mounting
Rack-mounting
Rack-mounting
Rack-mounting
Rack-mounting
CPU-mounting
CPU-mounting
CPU-mounting
CPU-mounting
Mounting Type
A Host Link Unit allows a host computer to monitor the operating status and data
areas of the PCs and to control the communications between the PCs and the
controlled system.
One Host Link Unit is required for each PC, and up to 32 PCs can be connected
to a single host computer. The Host Link Units described in this manual are re-
ferred to as “Rack-mounting” or “CPU mounting.” A Rack-mounting Host Link
Unit is mounted to an I/O slot of the CPU or Expansion I/O Rack of the building
block PC. A CPU-mounting Host Link Unit is mounted directly to the PC’s CPU.
Different types of Host Link Units, e.g., Rack-mounting and CPU-mounting, can
be combined so that the same PC can be connected to more than one Host Link
Unit. An example of a system using some of these combinations is provided in
1-2 System Configuration, along with other example configurations. Most of
these systems also employ Link Adapters, which are usually used in a system to
branch between Host Link Units, host computers, etc., or to interface wire cables
with optical fiber cables, or to perform both of these functions.
The following table gives the mounting method, types of connectors, and appli-
cable PCs for each of the Host Link Units dealt with in this manual.
The following examples illustrate possible applications of Host Link Units in
wired or optical systems, or both.
Some systems will comprise just one Host Link Unit connected to a single host
computer. This is known as a “single-link” system. Others systems might com-
prise many Host Link Units connected to a host computer. This configuration is
known as a “multiple-link” system. Although most systems will require only one
host computer, if both Rack-mounting and CPU-mounting Host Link Units are
C200H, C200HS, C200HX, C200HG,
and C200HE****
C200H, C200HS, C200HX, C200HG,
and C200HE****
C200H, C200HS, C200HX, C200HG,
and C200HE****
C500, C1000H, and C2000H
C500, C1000H, and C2000H
C500, C1000H, and C2000H
C500, C1000H, and C2000H
C500, C1000H, and C2000H
C500, C1000H, and C2000H
CjjH (V1 models), C200H, C120,
C500, C1000H, and C2000H
CjjH (V1 models), C200H, C120,
C500, C1000H, and C2000H
CjjH (V1 models), C200H, C120,
C500, C1000H, and C2000H
CjjH (V1 models), C200H, C120,
C500, C1000H, and C2000H
Applicable PCs
APF/PCF/H-PCF
RS-232C
RS-422
APF/PCF/H-PCF
APF/PCF/H-PCF
PCF/H-PCF
RS-232C/RS-422
PCF/H-PCF
RS-232C/RS-422
APF/PCF/H-PCF
PCF/H-PCF
RS-232C
RS-422
Connection*
Section 1-2

Related parts for C500BC031