C500BC031 Omron, C500BC031 Datasheet - Page 113

no-image

C500BC031

Manufacturer Part Number
C500BC031
Description
BACKPLANE
Manufacturer
Omron
Datasheet

Specifications of C500BC031

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Response Code List
4-45
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
1
2
2
2
2
A
A
A
A
A
A
A
B
Other
x16
1
0
1
2
3
4
B
C
D
0
1
2
3
4
5
6
8
9
0
1
2
3
0
1
2
3
4
5
8
0
x16
Response Code List
0
Command completed normally.
Execution was not possible because the PC is in RUN mode. Change the PC mode.
Execution was not possible because the PC is in MONITOR mode. Change the PC mode.
Execution was not possible because PROM is mounted. Change the unit to RAM or EEPROM.
Address overflow (data overflow). Check the program.
Execution was not possible because the PC is in PROGRAM mode. Change the PC mode.
Execution was not possible because the PC is in DEBUG mode. Change the PC mode.
Execution was not possible because the Host Link Unit’s keyswitch is set to LOCAL mode or because the
command was sent to a C2000H CPU that was on standby. Change the mode or send the command to
the active CPU.
Parity error.
Framing error (stop bit(s) not detected).
Overrun (the next command was received too soon).
FCS error (checksum error).
Command format error.
An incorrect data area designation was made for READ or WRITE.
Instruction not found.
Frame length error (maximum length exceeded).
Execution was not possible because of an unexecutable error clear, memory error, EEPROM write dis-
abled, etc.
I/O table generation was not possible (unrecognized Remote I/O Unit, word overflow, duplicated word
allocation).
An error occurred in the PC’s CPU.
The specified Memory Unit does not exist.
The specified Memory Unit is write-protected.
Aborted due to parity error in transmit data.
Aborted due to framing error in transmit data.
Aborted due to overrun in transmit data.
Aborted due to FCS (checksum) error in transmit data.
Aborted due to format error in transmit data.
Aborted due to entry number data error in transmit data.
Aborted due to frame length error in transmit data.
Not executable because the program area is not 16 kbytes.
Remove any possible causes of noise and resend the command.
A response code is returned with each response to a command to indicate the
results of executing the command. A response code of 00 indicates that the
command was completed normally. All other response codes indicate errors that
prevented proper command execution and tell something about the cause of the
error.
Description
Section 4-45
97

Related parts for C500BC031