XS1M18MA230 SQUARE D, XS1M18MA230 Datasheet - Page 69

Inductive Proximity Sensor

XS1M18MA230

Manufacturer Part Number
XS1M18MA230
Description
Inductive Proximity Sensor
Manufacturer
SQUARE D
Datasheet

Specifications of XS1M18MA230

Sensor Input
Inductive
Sensing Range
5mm
Supply Voltage Range Ac
24V To 240V
Sensor Output
NO
Peak Reflow Compatible (260 C)
No
Sensor Housing
Cylindrical
Sensing Range Max
5mm
Output Type
NO
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Wiring
For additional cable options and lengths see p. 518
Accessories . . . . . . . . . . . . . . . . . . . . page 298, 316
10/02
Connector Cables (M12 or D suffix)
XSZCD101Y Micro Conn., 4 pin, 2 m, straight
XSZCD111Y Micro Conn., 4 pin, 2 m, 90°
Connector
4
1
4 wire programmable
NO or NC selectable output
PNP
NPN
XSZE
XSZB1
3
2
BN/1 (NO), BU/3 (NC)
BU/3 (NO), BN/1 (NC)
BN/1 (NO), BU/3 (NC)
BU/3 (NO), BN/1 (NC)
WH/2
BK/4
WH/2
kkk
BK/4
kk
Cable
Blue
Brown
Black
-
-
+
+
9006PA
BU –
BN +
BK Output
kk
XS Inductive Sensors / Ferrous/Non-Ferrous; Universal, DC
Specifications
Accessories
Standard sensor technology requires an
adjustment of up to 70% of the sensing
distance to detect various metals. Because the
Ferrous/Non-Ferrous sensor detects all
metals at the same distance, compensation is
no longer needed. A smaller device can now
perform at a range comparable to a larger
sized or non-shielded device.
Mechanical
Standard Temperature Range
Enclosure Rating
Enclosure Material
Tightening torque (max.)
Vibration resistance
Shock resistance
Standard Target Size
Differential (max)
Repeatability (max)
LED indicator type
Connection
Electrical
Voltage Range
Voltage Limit (including ripple)
Voltage Drop (across switch) closed state (max)
Current consumption (no load) (max)
Load Current (max)
Operating frequency (max)
On delay (max)
Off delay (max)
Power-up delay (max)
Short circuit protection
Overload protection
Reverse polarity protection
Protective circuitry
Agency Listings
Size
18 mm
18 mm
18 mm
30 mm
30 mm
30 mm
©
1997-2002 Schneider Electric All Rights Reserved
Description
Metal mounting nuts
Metal mounting bracket
Plastic mounting bracket
Stainless steel mounting nuts
Metal mounting bracket
Plastic mounting bracket
NEMA Type
IEC Type
Case
(IEC 60068-2-6)
(IEC 60068-2-27)
0.7" (18 mm)
1.18" (30 mm)
Limit switch
(% of Sr.)
(% of Sr.)
Tubular, cable
Tubular, connector
Tubular, pigtail
Limit switch body
10.7" (8 mm) cable
0.7" (18 mm) connector
1.18" (30 mm) cable
1.18" (30 mm) pigtail
Limit switch body
Radio Frequency Immunity (RFI)
Electrostatic, Transients, Impulse
®
E 164869
CCN NRKH
100
90
80
70
60
50
40
30
20
10
0
Steel
Mag.
Ferrous/Non-Ferrous; Universal, DC
32° to 122° F (0° to 50° C)
Tubular, cable3, 4X, 6P, 12,13
Tubular, connector See connector rating
Limit switch body
Tubular, cable
Tubular, connectorSee connector rating
Limit Switch BodyIEC IP67
XS1M18
XS1M30
XS7
XS1M1835 N•m
XS1M3050 N•m
7 gn, amplitude ± 1mm (f = 10 Hz to 42 Hz)
0.7" x 0.7" (18 mm x 18 mm)
1.18" x 1.18" (30 mm x 30 mm)
1.77" x 1.77" (45 mm x 45 mm)
3%
360° ring LED
4 LED windows at 90°
360° ring LED
LED power On
4 wire #22 AWG (0.34 mm
4 pin Micro Style DC
4 wire #22 AWG (0.34 mm
4 pin Micro Style DC, 0.8 m (2.6’) pigtail, PvR
#14 AWG Screw Terminals
12 - 24 Vdc
10 - 38 Vdc
15 mA
200 mA
1000 Hz.
5 ms
Yes
Yes
Yes
IEC 60947-5-2 and NEMA ICS 5, Part 4
30 gn, duration 11 ms
15%
2.6 V
0.3 ms
0.7 ms
Standard vs. Fe/NonFe Prox
Sensing Range (%)
CR 44087
Class 3211 03
Stainless
Steel
304
Nickel Plated Brass
Stainless Steel
ABS Plastic
4, 6P, 12
IEC IP68
XS Inductive Sensors
Alu
Proximity Sensors
2
2
), PvR
), PvR
Catalog Number
XSZE118
9006PA18
XSZB118
XSZE330
9006PA30
XSZB130
Cu
std
Fe/NFe
265

Related parts for XS1M18MA230