XS1M18MA230 SQUARE D, XS1M18MA230 Datasheet - Page 156

Inductive Proximity Sensor

XS1M18MA230

Manufacturer Part Number
XS1M18MA230
Description
Inductive Proximity Sensor
Manufacturer
SQUARE D
Datasheet

Specifications of XS1M18MA230

Sensor Input
Inductive
Sensing Range
5mm
Supply Voltage Range Ac
24V To 240V
Sensor Output
NO
Peak Reflow Compatible (260 C)
No
Sensor Housing
Cylindrical
Sensing Range Max
5mm
Output Type
NO
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Proximity Sensors
Sensing Distance Correction Factors
352
Sensing Distance Correction Factors
For all situations, use the general correction factor Kt = 0.9 for power supply variations within
the entire voltage range.
Sa = Sn x KΘ x Km x Kd x Kt
Where
Proximity sensor XS7C40MP230 with nominal sensing distance Sn = 15 mm.
Ambient temperature variation 0° C to + 20° C.
Target characteristics:
The operating zone, Sa can be found using the formula:
For standard targets, the rule of thumb is:
Dimension
The above curves are typical curves only. They are given as a guide to
the approximate usable sensing distance of a proximity sensor for a
given application
Sa = Sn x KΘ x Km x Kd x Kt
Sa = 15 x 0.98 x 1 x 0.95 x 0.9
Sa = 12.5 mm
Sa = 0.8 Sn
Apply a correction factor Kd to be determined using the curve above.
Kd
©
1997-2002 Schneider Electric All Rights Reserved
Sn = nominal sensing distance
material: Steel
dimensions: 45 mm x 45 mm x 1 mm
Sa = usable sensing distance
0.9
0.8
0.7
0.6
0.5
0.4
0,3
0.2
0.1
1
Sn
2Sn
3Sn
4 Sn
length of the
object to be
detected
10/02

Related parts for XS1M18MA230