SP100R BANNER ENGINEERING, SP100R Datasheet - Page 11

no-image

SP100R

Manufacturer Part Number
SP100R
Description
PHOTO SENSOR RECEIVER
Manufacturer
BANNER ENGINEERING
Datasheet

Specifications of SP100R

Output Current
150mA
Sensor Output
NPN Open Collector
Supply Voltage Range Dc
10V To 30V
Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
MICRO-AMP
MA4-2 One-Shot Logic Module
MICRO-AMP
length. It is designed as a way to easily add one-shot timing to a MICRO-AMP system which
uses an MA3 or MA3-4 amplifier. It may also be used to add a one-shot timer to any current
sinking DC device or to a system which offers a contact closure output.
A low-going logic
#5 and #6, unless a low-going logic
Both
Both are NPN open-collector (current sinking) transistors, each capable of switching up to 150
milliamps.
Three pulse duration time ranges are selectable. The .001 to .1 second range is standard, and
.01 to 1 second and 1 to 15 second ranges are selected by connecting the appropriate module
pin to pin #3 (dc common). The MA4-2 is a retriggerable-type one-shot, but may easily be programmed
to the non-retriggerable mode by connecting pin #6 (N/O output) to pin #8 (
MICRO-AMP MA4-2 Specifications
SUPPLY VOLTAGE: 10 to 30V dc at less than 20 milliamps (exclusive of load); 10% maximum
ripple.
INPUTS: INPUT and INHIBIT both respond to a logic "low" signal (less than 2V dc). A logic "high"
is at least 6V dc or an open circuit. Inputs must be capable of sinking at least 4 milliamps. Inputs may be derived from limit switches or from
dc sensors with NPN (current sinking) output transistors.
RESPONSE SPEED: INPUT and INHIBIT will respond to a low signal or high signal of 1 millisecond duration or longer.
OUTPUT CONFIGURATION: two open-collector NPN transistors with complementary outputs (one normally open, one normally closed).
Maximum sinking current 150 milliamps, each output. Saturation voltage less than 0.5V dc at 10 milliamps. Off-state leakage current less
than 1 microamp.
PULSE DURATION: standard range is .001 to .1 second. Programmable ranges are .01 to 1 second and 1 to 15 seconds.
Select the .01 to 1 second range by connecting pin #2 to pin #3. Select the 1 to 15 second range by connecting #1 to #3.
TIMING ADJUSTMENT: single-turn timing potentiometer allows adjustment of pulse duration within the selected range (use small flat-
bladed screwdriver).
INDICATOR: red LED indicator on the top of the module lights whenever the N/O output is conducting (i.e. when the N/O output is closed
and the N/C output is open).
CONSTRUCTION: totally encapsulated plug-in package with molded VALOX
OPERATING TEMPERATURE: 0 to 70 degrees C (32 to 158 degrees F).
Retriggerable one-shot logic:
There are two types of basic "one-shots": RETRIGGERABLE and NON-
RETRIGGERABLE. The output pulse timing of a retriggerable one-shot is re-
started with the reoccurance of every input. The output will remain "on" as
long as the time between consecutive inputs is shorter than the one-shot pulse
time (see timing diagram, below).
Functional Schematic, MA4-2 ONE-SHOT Module
NORMALLY OPEN
OUTPUT
INPUT
®
module MA4-2 is a plug-in one-shot logic module with adjustable pulse
INPUT
Pulse
signal at pin #7 of the module activates a one-shot output at both pins
(pin #6) and
INHIBIT
NORMALLY CLOSED
®
signal is present at pin #8 when the input occurs.
System
Hold
Pulse
(pin #5) outputs are available.
A non-retriggerable one-shot timer must complete a pulse before it will
accept any new input signals. Non-retriggerable one-shots sometimes offer
an advantage in indexing or registration control applications where multiple
input signals are possible during advance of the product. The MA4-2 may
be programmed for the non-retriggerable mode by connecting pin #6 to pin
#8.
Non-retriggerable one-shot logic:
INHIBIT
Hookup Diagram, MA4-2 ONE-SHOT Module
OUTPUT
INPUT
®
input).
housing. Gold-flashed connection pins.
Pulse
Pulse
OUTPUT
INHIBIT
INPUT
One-shot logic, MA4-2:
Pulse
Pulse
Pulse
11

Related parts for SP100R