CS5460A-BS Cirrus Logic Inc, CS5460A-BS Datasheet - Page 39

Driver IC

CS5460A-BS

Manufacturer Part Number
CS5460A-BS
Description
Driver IC
Manufacturer
Cirrus Logic Inc
Datasheet

Specifications of CS5460A-BS

Peak Reflow Compatible (260 C)
No
Supply Voltage Max
5V
Driver Case Style
SSOP
Leaded Process Compatible
No
Mounting Type
Surface Mount
Package / Case
24-SSOP
Mounting Style
SMD/SMT
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CS5460A-BS
Manufacturer:
CIRRUS
Quantity:
20 000
Company:
Part Number:
CS5460A-BS
Quantity:
59
Part Number:
CS5460A-BSZ
Manufacturer:
CIRRUS
Quantity:
2
Part Number:
CS5460A-BSZ
Manufacturer:
CIRRUS
Quantity:
1 574
Part Number:
CS5460A-BSZ
Manufacturer:
ALTERA
0
Part Number:
CS5460A-BSZ
0
Part Number:
CS5460A-BSZR
Manufacturer:
CIRRUS
Quantity:
8 000
Part Number:
CS5460A-BSZR
Manufacturer:
CIRRUS
Quantity:
20 000
4.1 Commands (Write Only)
All command words are 1 byte in length. Commands that write to a register must be followed by 3 bytes of register
data. Commands that read from registers initiate the output of 3 bytes of register data. Commands that read data
can be ‘chained’ with other commands (e.g., while reading data, a new command can be sent to SDI which can ex-
ecute before the original read is completed). This allows for ‘chaining’ commands.
4.1.1 Start Conversions
This command indicates to the state machine to begin acquiring measurements and calculating results. The device
has two modes of acquisition.
4.1.2 SYNC0 Command
This command is the end of the serial port re-initialization sequence. It can also be used as a NOP command. The
serial port is resynchronized to byte boundaries by sending three or more consecutive SYNC1 commands followed
by a SYNC0 command.
4.1.3 SYNC1 Command
This command is part of the serial port re-initialization sequence. It can also serve as a NOP command.
4.1.4 Power-Up/Halt
If the device is powered-down into either stand-by or sleep power saving mode (See 4.1.5), this command will pow-
er-up the device. After the CS5460A is initially powered-on, no conversions/computations will be running. If the de-
vice is already powered on and the device is running either ‘single computation cycle’ or ‘continuous computation
cycles’ data acquisition modes, all computations will be halted once this command is received.
DS487F4
Modes of acquisition/measurement
B7
B7
B7
B7
1
1
1
1
B6
B6
B6
B6
0 = Perform a single computation cycle
1 = Perform continuous computation cycles
1
1
1
0
B5
B5
B5
B5
1
1
1
1
B4
B4
B4
B4
0
1
1
0
B3
B3
B3
B3
C
1
1
0
B2
B2
B2
B2
0
1
1
0
B1
B1
B1
B1
0
1
1
0
CS5460A
B0
B0
B0
B0
0
0
1
0
39