AT80C51RD2-3CSUM Atmel, AT80C51RD2-3CSUM Datasheet - Page 44

no-image

AT80C51RD2-3CSUM

Manufacturer Part Number
AT80C51RD2-3CSUM
Description
IC, 8BIT MCU, 80C51, 40MHZ, DIP-40
Manufacturer
Atmel
Datasheet

Specifications of AT80C51RD2-3CSUM

Controller Family/series
80C51
No. Of I/o's
32
Ram Memory Size
1280Byte
Cpu Speed
40MHz
No. Of Timers
3
No. Of Pwm Channels
5
Digital Ic Case Style
DIP
Core Size
8 Bit
Rohs Compliant
Yes
Processor Series
AT80x
Core
8051
Data Bus Width
8 bit
Program Memory Type
ROMLess
Data Ram Size
1280 B
Interface Type
UART, SPI
Maximum Clock Frequency
60 MHz
Number Of Programmable I/os
32
Number Of Timers
3
Operating Supply Voltage
2.7 V to 5.5 V
Maximum Operating Temperature
+ 70 C
Mounting Style
Through Hole
Package / Case
PDIL-40
3rd Party Development Tools
PK51, CA51, A51, ULINK2
Minimum Operating Temperature
0 C
Cpu Family
AT80
Device Core
8051
Device Core Size
8b
Frequency (max)
40MHz
Program Memory Size
Not Required
Total Internal Ram Size
1.25KB
# I/os (max)
32
Number Of Timers - General Purpose
3
Operating Supply Voltage (typ)
3.3/5V
Operating Supply Voltage (max)
5.5V
Operating Supply Voltage (min)
2.7V
Instruction Set Architecture
CISC
Operating Temp Range
-40C to 85C
Operating Temperature Classification
Industrial
Mounting
Through Hole
Pin Count
40
Package Type
PDIP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
44
AT80C51RD2
Table 11-13. BDRCON Register
BDRCON - Baud Rate Control Register (9Bh)
Reset Value = XXX0 0000b
Not bit addressable
Number
Bit
7
-
7
6
5
4
3
2
1
0
Mnemonic
RBCK
TBCK
BRR
SPD
SRC
6
Bit
-
-
-
-
Description
Reserved
The value read from this bit is indeterminate. Do not set this bit
Reserved
The value read from this bit is indeterminate. Do not set this bit
Reserved
The value read from this bit is indeterminate. Do not set this bit.
Baud Rate Run Control bit
Cleared to stop the internal Baud Rate Generator.
Set to start the internal Baud Rate Generator.
Transmission Baud rate Generator Selection bit for UART
Cleared to select Timer 1 or Timer 2 for the Baud Rate Generator.
Set to select internal Baud Rate Generator.
Reception Baud Rate Generator Selection bit for UART
Cleared to select Timer 1 or Timer 2 for the Baud Rate Generator.
Set to select internal Baud Rate Generator.
Baud Rate Speed Control bit for UART
Cleared to select the SLOW Baud Rate Generator.
Set to select the FAST Baud Rate Generator.
Baud Rate Source select bit in Mode 0 for UART
Cleared to select F
Set to select the internal Baud Rate Generator for UARTs in mode 0.
5
-
BRR
OSC
4
/12 as the Baud Rate Generator (F
TBCK
3
RBCK
2
CLK PERIPH
SPD
1
/6 in X2 mode).
4113D–8051–01/09
SRC
0