UART, 2 CH, 16BYTE FIFO, 16C2552

SC16C2552BIA44

Manufacturer Part Number
SC16C2552BIA44
Description
UART, 2 CH, 16BYTE FIFO, 16C2552
Manufacturer
NXP Semiconductors
Datasheet

Specifications of SC16C2552BIA44

No. Of Channels
2
Data Rate
5Mbps
Supply Voltage Range
2.25V To 5.5V
Operating Temperature Range
-40°C To +85°C
Digital Ic Case Style
PLCC
No. Of Pins
44
Svhc
No SVHC (18-Jun-2010)
Operating
RoHS Compliant
Uart Features
Independent Transmit & Receive UART Control, Multi-Function Output, Modem Control Functions
Rohs Compliant
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SC16C2552BIA44
Quantity:
2 240
Part Number:
SC16C2552BIA44
Manufacturer:
NXP/恩智浦
Quantity:
20 000
Part Number:
SC16C2552BIA44,529
Manufacturer:
NXP Semiconductors
Quantity:
10 000
NXP Semiconductors
SC16C2552B_3
Product data sheet
Table 8.
Table 9.
Bit
3
(continued)
2
1
0
FCR[7]
0
0
1
1
FIFO Control Register bits description
RCVR trigger levels
Symbol
FCR[2]
FCR[1]
FCR[0]
FCR[6]
0
1
0
1
5 V, 3.3 V and 2.5 V dual UART, 5 Mbit/s (max.), with 16-byte FIFOs
Rev. 03 — 12 February 2009
Description
Transmit operation in mode ‘1’: When the SC16C2552B is in FIFO
mode (FCR[0] = logic 1; FCR[3] = logic 1), the TXRDYn pin will be a
logic 1 when the transmit FIFO is completely full. It will be a logic 0 if
one or more FIFO locations are empty.
Receive operation in mode ‘1’: When the SC16C2552B is in FIFO
mode (FCR[0] = logic 1; FCR[3] = logic 1) and the trigger level has been
reached, or a Receive Time-out has occurred, the RXRDY signal at the
MFn pin will go to a logic 0. Once activated, it will go to a logic 1 after
there are no more characters in the FIFO. Note that the AFR register
must be set to the RXRDY mode prior to any possible reading of the
RXRDY signal.
XMIT FIFO reset.
RCVR FIFO reset.
FIFOs enabled.
logic 0 = no FIFO transmit reset (normal default condition)
logic 1 = clears the contents of the transmit FIFO and resets the FIFO
counter logic (the Transmit Shift Register is not cleared or altered).
This bit will return to a logic 0 after clearing the FIFO.
logic 0 = no FIFO receive reset (normal default condition)
logic 1 = clears the contents of the receive FIFO and resets the FIFO
counter logic (the Receive Shift Register is not cleared or altered).
This bit will return to a logic 0 after clearing the FIFO.
logic 0 = disable the transmit and receive FIFO (normal default
condition)
logic 1 = enable the transmit and receive FIFO. This bit must be a ‘1’
when other FCR bits are written to or they will not be
programmed.
RX FIFO trigger level
01
04
08
14