LIS302DLH STMicroelectronics, LIS302DLH Datasheet - Page 29

SENSOR ACCELEROMETER 3AXIS 14LGA

LIS302DLH

Manufacturer Part Number
LIS302DLH
Description
SENSOR ACCELEROMETER 3AXIS 14LGA
Manufacturer
STMicroelectronics
Datasheet

Specifications of LIS302DLH

Featured Product
STM32 Cortex-M3 Companion Products
Axis
X, Y, Z
Acceleration Range
±2.3g, 9.2g
Sensitivity
18mg/digit, 72mg/digit
Voltage - Supply
2.16 V ~ 3.6 V
Output Type
Digital
Bandwidth
100Hz ~ 400Hz Selectable
Interface
I²C, SPI
Mounting Type
Surface Mount
Package / Case
14-LGA
Package Type
LGA
Operating Supply Voltage (min)
2.16V
Operating Supply Voltage (typ)
2.5V
Operating Supply Voltage (max)
3.6V
Operating Temperature (min)
-40C
Operating Temperature (max)
85C
Operating Temperature Classification
Industrial
Product Depth (mm)
3mm
Product Height (mm)
0.92mm
Product Length (mm)
5mm
Mounting
Surface Mount
Pin Count
14
Sensing Axis
Triple
Acceleration
2 g, 4 g, 8 g
Digital Output - Number Of Bits
16 bit
Supply Voltage (max)
3.6 V
Supply Voltage (min)
2.16 V
Maximum Operating Temperature
+ 85 C
Minimum Operating Temperature
- 40 C
Digital Output - Bus Interface
I2C, SPI
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
497-10052

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LIS302DLHS0.5
Manufacturer:
INNOLUX
Quantity:
1 000
Part Number:
LIS302DLHTR
Manufacturer:
SANYO
Quantity:
11
LIS302DLH
7.7
7.8
7.9
CTRL_REG1. Although the device is in normal mode, CTRL_REG1 content is not
automatically changed to “normal mode” configuration.
HP_FILTER_RESET (25h)
Dummy register. Reading at this address zeroes instantaneously the content of the internal
high pass-filter. If the high pass filter is enabled all three axes are instantaneously set to 0g.
This allows to overcome the settling time of the high pass filter.
REFERENCE (26h)
Table 33.
Table 34.
This register sets the acceleration value taken as a reference for the high-pass filter output.
When filter is turned on (at least one of FDS, HPen2, or HPen1 bit is equal to ‘1’) and HPM
bits are set to “01”, filter out is generated taking this value as a reference.
STATUS_REG (27h)
Table 35.
Table 36.
Ref7 - Ref0
ZYXOR
ZOR
YOR
XOR
ZYXOR
Ref7
REFERENCE register
REFERENCE description
STATUS_REG register
STATUS_REG description
X, Y and Z axis data overrun. Default value: 0
(0: no overrun has occurred;
1: new data has overwritten the previous one before it was read)
Z axis data overrun. Default value: 0
(0: no overrun has occurred;
1: a new data for the Z-axis has overwritten the previous one)
Y axis data overrun. Default value: 0
(0: no overrun has occurred;
1: a new data for the Y-axis has overwritten the previous one)
X axis data overrun. Default value: 0
(0: no overrun has occurred;
1: a new data for the X-axis has overwritten the previous one)
Reference value for high-pass filter. Default value: 00h.
Ref6
ZOR
Ref5
YOR
Doc ID 15797 Rev 1
XOR
Ref4
ZYXDA
Ref3
Ref2
ZDA
Register description
Ref1
YDA
Ref0
XDA
29/37