L6470H STMicroelectronics, L6470H Datasheet - Page 57

Motor / Motion / Ignition Controllers & Drivers 8 - 45V 7.0A 1/128 Microstepping SPI

L6470H

Manufacturer Part Number
L6470H
Description
Motor / Motion / Ignition Controllers & Drivers 8 - 45V 7.0A 1/128 Microstepping SPI
Manufacturer
STMicroelectronics
Type
Micro Stepping Motor Driverr
Series
-r
Datasheet

Specifications of L6470H

Product
Stepper Motor Controllers / Drivers
Operating Supply Voltage
8 V to 45 V
Supply Current
0.5 mA
Mounting Style
SMD/SMT
Package / Case
HTSSOP-28
Operating Temperature
- 40 C to + 125 C
Applications
Stepper Motor Driver, 2 Phase
Evaluation Tools
*
Number Of Outputs
1
Current - Output
3A
Voltage - Load
8 V ~ 45 V
Voltage - Supply
3.3V, 5V
Mounting Type
*
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
L6470H
Manufacturer:
STMicroelectronics
Quantity:
135
Part Number:
L6470H
Manufacturer:
ST
0
Part Number:
L6470H
Manufacturer:
ST
Quantity:
20 000
Part Number:
L6470H
0
Company:
Part Number:
L6470H
Quantity:
50
Company:
Part Number:
L6470H
Quantity:
50
Part Number:
L6470HTR
Manufacturer:
ST
0
Part Number:
L6470HTR
Manufacturer:
ST
Quantity:
20 000
Part Number:
L6470HTR
0
Company:
Part Number:
L6470HTR
Quantity:
9 000
L6470
9.2.9
9.2.10
GoTo_DIR (DIR, ABS_POS)
Table 44.
The GoTo_DIR command produces a motion to ABS_POS absolute position imposing a
forward (DIR = '1') or a reverse (DIR = '0') rotation. The ABS_POS value is always in
agreement with the selected step mode; the parameter value unit is equal to the selected
step mode (full, half, quarter, etc.).
This command can be given when the outputs are in high impedance or the motor is
stopped or running with constant speed.
Any attempt to perform a GoTo_DIR command when a previous command is under
execution (BUSY low) causes the command to be ignored and the NOTPERF_CMD flag to
rise (see paragraph
GoUntil (ACT, DIR, SPD)
Table 45.
The GoUntil command produces a motion at SPD speed imposing a forward (DIR = '1') or a
reverse (DIR = '0') direction. When an external switch turn-on event occurs (see paragraph
6.13
into the MARK register (if ACT = '1'); then the system performs a SoftStop command.
The SPD value is expressed in step/tick (format unsigned fixed point 0.28) that is the same
format that SPEED register (see paragraph
SPD value should be lower than MAX_SPEED and greater than MIN_SPEED, otherwise the
target speed will be imposed at MAX_SPEED or MIN_SPEED respectively.
If SW_MODE bit of CONFIG register is set low, the external switch turn-on event causes a
HardStop interrupt instead of the SoftStop command (see paragraphs
This command can be given anytime and is immediately executed.
Bit 7
Bit 7
X
X
0
1
), the ABS_POS register is reset (if ACT = '0') or the ABS_POS register value is copied
Bit 6
Bit 6
X
0
GoTo_DIR command structure
X
GoUntil command structure
1
Bit 5
9.1.22
Bit 5
X
0
1
)
ABS_POS (Byte 1)
ABS_POS (Byte 0)
Bit 4
Bit 4
SPD (Byte 1)
SPD (Byte 0)
Doc ID 16737 Rev 2
X
0
0
ABS_POS (Byte 2)
Bit 3
ACT
Bit 3
1
9.1.4
Bit 2
Bit 2
SPD (Byte 2)
0
).
0
Bit 1
Bit 1
1
0
Bit 0
DIR
Bit 0
DIR
Programming manual
6.13
and
from host
from host
from host
from host
from host
from host
from host
from host
9.1.21
).
57/64

Related parts for L6470H