WM8351GEB/V Wolfson Microelectronics, WM8351GEB/V Datasheet - Page 296

no-image

WM8351GEB/V

Manufacturer Part Number
WM8351GEB/V
Description
Audio CODECs Audio CODEC plus pwr management
Manufacturer
Wolfson Microelectronics
Datasheet

Specifications of WM8351GEB/V

Number Of Adc Inputs
2
Number Of Dac Outputs
2
Conversion Rate
48 KSPS
Interface Type
Serial (2-Wire, 3-Wire, 4-Wire)
Resolution
12 bit
Operating Supply Voltage
3.7 V
Maximum Operating Temperature
+ 85 C
Mounting Style
SMD/SMT
Package / Case
BGA
Minimum Operating Temperature
- 25 C
Number Of Channels
2 ADC/2 DAC
Supply Current
260 uA
Thd Plus Noise
- 83 dB
Audio Codec Type
Stereo
No. Of Adcs
2
No. Of Dacs
2
No. Of Input Channels
8
No. Of Output Channels
6
Adc / Dac Resolution
24bit
Adcs / Dacs Signal To Noise Ratio
95dB
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
WM8351
Register BBh DCDC3 Timeouts
REGISTER
w
REGISTER
ADDRESS
DCDC3 Low
ADDRESS
R188 (BCh)
R187 (BBh)
Timeouts
DCDC3
Power
14:12
15:14
13:10
BIT
BIT
9:8
6:0
9:6
DC3_HIB_MODE[2:0]
DC3_ERRACT[1:0]
DC3_ENSLOT[3:0]
DC3_SDSLOT[3:0]
DC3_HIB_TRIG[1:0]
DC3_VIMG[6:0]
LABEL
LABEL
DEFAULT
DEFAULT
000_0110
0000
0001
0001
0010
0000
00
000
00
Action to take on DC-DC3 fault (as well as
generating an interrupt):
00 = ignore
01 = shut down converter
10 = shut down system
11 = reserved (shut down system)
Reset by state machine. Default held in metal
mask.
Time slot for DC-DC3 start-up
0000 = Disabled (do not start up)
0001 = Start-up in time slot 1
… (total 14 slots available)
1110 = Start-up in time slot 14
1111 = Start-up on entering ACTIVE
Reset by state machine. Default held in metal
mask.
Time slot for DC-DC3 shutdown.
0000 = Shut down on entering OFF
0001 = Shutdown in time slot 1
…. (total 14 slots available)
1110 = Shutdown in time slot 14
1111 = Shut down on entering OFF
DC-DC3 Hibernate behaviour:
000 = Use current settings (no change)
001 = Select voltage image settings
010 = Force standby mode
011 = Force standby mode and voltage image
settings.
100 = Force LDO mode
101 = Force LDO mode and voltage image
settings.
110 = Reserved.
111 = Disable output
Reset by state machine. Default held in metal
mask.
DC-DC3 Hibernate signal select
00 = HIBERNATE register bit
01 = L_PWR1
10 = L_PWR2
11 = L_PWR3
Note that Hibernate is also selected when a
GPIO Hibernate input is asserted.
Reset by state machine. Default held in metal
mask.
DC-DC3 Converter output image voltage settings
in 25mv steps.
Maximum output = 3.4V.
110 0110 = 3.4V
110 0010 = 3.3V
DESCRIPTION
DESCRIPTION
PD, March 2010, Rev 4.2
REFER TO
REFER TO
Production Data