AN3097
Note:
3.2.13
Each loop created with if, goto or repeat statement must include a delay statement,
otherwise the program does not respond to the STOP command.
The execution time of a write or writevar instruction is about 6 ms, read about 9 ms and
readtemperature about 35 ms. The other operations are faster and depend on the PC used.
The readtemperature instruction changes the A-to-D converter settings.
The numbers written in the window field are intended as hex values.
For more details on device registers refer to the L6460 user manual.
How to read the device temperature
The internal A-D converter can be used to measure a voltage proportional to the IC
temperature; you can display the resulting temperature directly by pushing the "Thermal
Manager" button in the L6460 window
button, the value read starts to appear in the graph: yellow is sensor 1 and cyan is sensor 2
(time division 2 seconds).
To choose a statement use the + or - buttons near the "Statement" field. The instruction
set is:
Add/sub/mul/div: add/subtract/multiply/divide a variable and a constant, the result
is put into the variable register
Inc/dec: increment/decrement a variable of 1 unit
Logicaland/or/exor: make the and/or/exor logical operation between a variable and
a constant. The result is put into the variable register
Compare: compare a variable with a constant. The result indicates that the
variable is lesser, equal or greater than the constant
Delay: stop the execution for a specified time expressed in milliseconds
End: indicate the end of the program, it must be the last statement
Label: assign a label to the statement (hex format)
Goto: jump to the label indicated
If: continue the execution starting from a label until the result of compare is the set
one, otherwise jump to the successive statement
Read: read the register value and assign it to a variable
Readtemperature: read the device temperature using the integrates A-to-D. The
value is displayed in the "Temperature" window
Repeat: repeat the label for the indicated times
Setdigio: no operation
Stopprocedure: set the routine which is executed if the STOP button is pushed
Write: write a constant in the indicated device register (hex format)
Writevar: write a variable in the indicated device register (hex format)
Doc ID 16599 Rev 2
(Figure
The EVAL6460 controlled by the EVAL_IBU-STR7
36). By pushing the "Start Thermometer"
31/34