IS-C0203-F-E NKK Switches, IS-C0203-F-E Datasheet - Page 8

SMARTSWITCH CONTROLLER LCD

IS-C0203-F-E

Manufacturer Part Number
IS-C0203-F-E
Description
SMARTSWITCH CONTROLLER LCD
Manufacturer
NKK Switches
Datasheets

Specifications of IS-C0203-F-E

Accessory Type
Controller
Description/function
SMARTSWITCH Development Kit
For Use With/related Products
SmartSwitch™ Switches
For Use With
360-2345 - SWITCH COMPACT LCD 64X32 RGB360-2343 - SWITCH LCD 64X32 RGB360-2341 - DISPLAY LCD 64X32IS01BCEF - SMARTDISPLAY SUPER YEL/GRN LEDIS01BCE - SMARTDISPLAY SUPER YELLOW LEDIS15SBFP4B - SMARTSWITCH COMPACT WHITE LEDIS15SBCP4EF - SMARTSWITCH COMPACT YEL/GRN LEDIS15SACP4CF - SMARTSWITCH COMPACT RED/GRN LEDIS15ABFP4B - SMARTSWITCH STD BLK W/WHITE LEDIS15ABDP4B - SMARTSWITCH STD BLU W/WHITE LEDIS15ABDP4EG - SMARTSWITCH STD YELLOW/BLUE LEDIS15ABDP4E - SMARTSWITCH STD BLUE W/YEL LEDIS15ABCP4EF - SMARTSWITCH STD YEL/GRN LEDIS15ABCP4E - SMARTSWITCH STD LED YELLOWIS15AACP4CF - SMARTSWITCH STD YEL RED/GRN LED360-2334 - SMARTDISPLAY RED/GREEN/BLUE360-2333 - SMARTDISPLAY SUPER RED/GREEN LED360-2332 - SMARTSWITCH STANDARD RED/GRN/BLU360-2331 - SMARTSWITCH COMPACT RED/GRN/BLU360-2330 - SMARTSWITCH STD RED/GRN LED360-2329 - SMARTSWITCH COMPACT RED/GRN LED
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
360-2425
7850 East Gelding Drive • Scottsdale, AZ 85260-3420
Attributes Execution
When a switch is pressed the attributes are executed as follows:
When one of the timers is expired the attributes are executed as follows:
Timers Operation
A. The timer for the switch is reset and does not run until the switch is released.
B. If byte 1 of the switch attributes is not equal to zero then the Legend block and attribute block from the
C. If byte 1 of the switch attributes is equal zero then there will be no change to Legend/attribute of the
D. If byte 2 of the switch attributes is not equal to zero then the Legend block and attribute block from the
E. If byte 2 of the switch attributes is equal zero then there will be no change to Legend/attribute of the
A. The timer that expired gets reset.
B. Both timers will pause until attributes are executed.
C. If byte 3 of switch attributes is not equal zero then the Legend block and attribute block from the
D. If byte 3 of switch attributes is equal zero then there will be no change to Legend/attributes of the switch
E. If byte 4 of the switch attributes is not equal to zero then the Legend block and attribute block from the
F. If byte 4 of the switch attributes is equal zero then there will be no change to Legend/attribute of the
• Switch one and switch two timers run independently.
• Timer will be disabled if the timer 1 value is zero.
• The timer value in second = (TIMER 1)x(TIMER 2)x(0.0369)
• TIMER 2 = 0 counts as 256.
IS-Dev Kit-5 and IS-Dev Kit-6 Users Manual A.doc
F. If the switch two is released: Transmit B2H to host.
G. Checks the host communication buffer for data. If there is data, process them.
H. Go to step 5 section A
EEPROM is transferred to internal RAM for switch 1. The Legend, backlighting and timer values are
put in effect for switch 1.
switch 1.
EEPROM is transferred to internal RAM for switch 2. The Legend, backlighting and timer values are
put in effect for switch 2.
switch 2.
EEPROM is transferred to internal RAM for switch 1. The Legend, backlighting and timer values are
put in effect for switch 1.
1.
EEPROM is transferred to internal RAM for switch 2. The Legend, backlighting and timer values are
put in effect for switch 2.
switch 2.
(For details see Communication Protocol)
Toll Free 1.877.2BUYNKK (877.228.9655) • Phone 480.991.0942 • Fax 480.998.1435
IS-Dev Kit-5 and IS-Dev Kit-6 Users
www.nkkswitches.com • Email engineering@nkkswitches.com
Manual
Page 8 of 24
1209

Related parts for IS-C0203-F-E