IC TXRX 300MHZ-510MHZ 32-TQFN

SX1212IWLTRT

Manufacturer Part Number
SX1212IWLTRT
Description
IC TXRX 300MHZ-510MHZ 32-TQFN
Manufacturer
Semtech
Datasheet

Specifications of SX1212IWLTRT

Frequency
300MHz ~ 510MHz
Data Rate - Maximum
150kbps
Modulation Or Protocol
FSK, OOK
Applications
AMR, ISM, Home Automation, Process Control
Power - Output
12.5dBm
Sensitivity
-110dBm
Voltage - Supply
2.1 V ~ 3.6 V
Current - Receiving
3mA
Current - Transmitting
25mA
Data Interface
PCB, Surface Mount
Antenna Connector
PCB, Surface Mount
Operating Temperature
-40°C ~ 85°C
Package / Case
32-TQFN
Operating Temperature (min)
-40C
Operating Temperature (max)
85C
Operating Temperature Classification
Industrial
Modulation Type
FSK/OOK
Package Type
TQFN EP
Operating Supply Voltage (min)
2.1V
Operating Supply Voltage (typ)
2.5/3.3V
Operating Supply Voltage (max)
3.6V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Memory Size
-
Lead Free Status / Rohs Status
Supplier Unconfirmed
Other names
SX1212IWLTR

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SX1212IWLTRT
Manufacturer:
SEMTECH/美国升特
Quantity:
20 000
Part Number:
SX1212IWLTRT
0
Company:
Part Number:
SX1212IWLTRT
Quantity:
16 674
Company:
Part Number:
SX1212IWLTRT
Quantity:
13 674
The detailed description of the TXParam register is given in Table 31.
Table 31: TXParam Register Description
Name
InterpFilt
Pout
TX_zero_if
The detailed description of the OSCParam register is given in Table 32.
Table 32: OSCParam Register Description
Name
Clkout_on
Clkout_freq
Res
Rev 2 – June 18th, 2009
ADVANCED COMMUNICATIONS & SENSING
6.6. Transmitter Parameters - TXParam
6.7. Oscillator Parameters - OSCParam
Bits
7-4
3-1
0
Bits
6-2
1-0
7
Address (d)
26
26
26
Address
(d)
27
27
27
RW
r/w
r/w
r/w
RW
r/w
r/w
r/w
Description
Clkout control
0
1
Frequency of the signal provided on CLKOUT:
(d): 01111 (= 427 kHz)
Reserved
(d): “00”
fclkout =
fclkout
Description
Tx Interpolation filter cut off frequency:
(d): “0111” => f
Tx output power (1 step ≈ 3 dB):
000
001
010
011
100
101
110
111
Set the transmitter in zero-if architecture in tx mode
0 -> normal operation (d)
1-> zero-if operation (first if is set to zero and frequency deviation is not
used)
fc
Disabled
Enabled, Clk frequency set by Clkout_freq (d)
=
Page 64 of 77
200
=
12.5 dBm
12.5 dBm -1 step (d)
12.5 dBm – 2 steps
12.5 dBm – 3 steps
12.5 dBm – 4 steps
12.5 dBm – 5 steps
12.5 dBm – 6 steps
12.5 dBm – 7 steps
2 ⋅
f
kHz
xtal
Clkout
.
12
F
C
if Clkout_freq = “00000”
f
xtal
xtal
= 200 kHz
8 .
MHz
MHz
_
freq
.
1
+
otherwise
Val
(
InterpFilt
8
Tx
)
www.semtech.com