IC TXRX 300MHZ-510MHZ 32-TQFN

SX1212IWLTRT

Manufacturer Part Number
SX1212IWLTRT
Description
IC TXRX 300MHZ-510MHZ 32-TQFN
Manufacturer
Semtech
Datasheet

Specifications of SX1212IWLTRT

Frequency
300MHz ~ 510MHz
Data Rate - Maximum
150kbps
Modulation Or Protocol
FSK, OOK
Applications
AMR, ISM, Home Automation, Process Control
Power - Output
12.5dBm
Sensitivity
-110dBm
Voltage - Supply
2.1 V ~ 3.6 V
Current - Receiving
3mA
Current - Transmitting
25mA
Data Interface
PCB, Surface Mount
Antenna Connector
PCB, Surface Mount
Operating Temperature
-40°C ~ 85°C
Package / Case
32-TQFN
Operating Temperature (min)
-40C
Operating Temperature (max)
85C
Operating Temperature Classification
Industrial
Modulation Type
FSK/OOK
Package Type
TQFN EP
Operating Supply Voltage (min)
2.1V
Operating Supply Voltage (typ)
2.5/3.3V
Operating Supply Voltage (max)
3.6V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Memory Size
-
Lead Free Status / Rohs Status
Supplier Unconfirmed
Other names
SX1212IWLTR

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
SX1212IWLTRT
Manufacturer:
SEMTECH/美国升特
Quantity:
20 000
Part Number:
SX1212IWLTRT
0
Company:
Part Number:
SX1212IWLTRT
Quantity:
16 674
Company:
Part Number:
SX1212IWLTRT
Quantity:
13 674
SX1212
ADVANCED COMMUNICATIONS & SENSING
FIFO are lost. On the other hand if Tx_start_irq_0 = 0 then the extra bytes are kept into the FIFO. This opens up
the possibility of transmitting more than one packet by filling the FIFO with multiple packet messages.
It is not possible to receive multiple packets. Once a packet has been received and filled into the FIFO all its
content needs to be read i.e. the FIFO must be empty for a new packet reception to be initiated.
The Payload_ready interrupt goes high when the last payload byte is available in the FIFO and remains high until
all its data are read. Similar behavior is applicable to Adrs_match and CRC_OK interrupts.
The CRC result is available in the CRC_status bit as soon as the CRC_successful and Payload_ready interrupt
sources are triggered. In Rx mode, CRC_status is cleared when the complete payload has been read from the
FIFO. If the payload is read in Stby mode, then CRC_status is cleared when the user goes back to Rx mode and a
new Sync word is detected.
The Fifo_fill_method and Fifo_fill bits don’t have any meaning in the Packet mode and should be set to their default
values only.