XBP09-DMDK Digi International, XBP09-DMDK Datasheet - Page 29

no-image

XBP09-DMDK

Manufacturer Part Number
XBP09-DMDK
Description
KIT STARTER PROMESH XBEE PRO
Manufacturer
Digi International
Series
XBEE-PRO™r
Type
Transceiver, XBeePror

Specifications of XBP09-DMDK

Frequency
900MHz
Wireless Frequency
900 MHz
Interface Type
RS-232, USB, UART
Modulation
FHSS
Security
128 bit AES
Operating Voltage
3.3 V
Output Power
50 mW
Antenna
RPSMA
For Use With/related Products
Xbee-PRO Modules
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Other names
602-1130
XBee‐PRO® 900  OEM RF Modules
Identifies the UART data frame being
reported. If Frame ID = 0, no AT command
response will be given
Frame ID (Byte 5)
Identifies the UART data frame being reported.
Note: If Frame ID = 0 in AT Command Mode,
no AT Command Response will be given.
AT Command Response
Remote AT Command Request
64-bit Destination Address
Start Delimiter
Start Delimiter
Set to match the 64-bit address
of the destination, MSB first,
LSB last. Broadcast =
0x000000000000FFFF.
API Identifier Value: (0x88)
Response to previous command.
In response to an AT Command message, the module will send an AT Command Response
message. Some commands will send back multiple frames (for example, the ND (Node Discover)
command).
AT Command Response Frames.
API Identifier Value: (0x17)
Allows for module parameter registers on a remote device to be queried or set
Remote AT Command Request
0x7E
Frame ID (Byte 5 )
© 2008 Digi International, Inc.
0x7E
(bytes 6-13)
MSB
MSB
Length
Length
LSB
API Identifier
0x017
LSB
0x88
API Identifier
API-specific Structure
API-specific Structure
Command Name - Two
ASCII characters that
identify the AT Command.
Frame Data
AT Command (Bytes 6-7)
Set to match the 16-bit network
address of the destination, MSB
first, LSB last. Set to 0xFFFE for
broadcast TX, or if the network
address is unknown.
Identifier-specific Data
Frame Data
16-bit Destination Network Address
Identifier-specific Data
Command Options (byte 16)
cmdData
cmdData
(bytes 14-15)
0x02 - Apply changes on remote. (If
not set, AC command must be sent
before changes will take effect.)
All other bits must be set to 0.
Checksum
1 Byte
Checksum
1 Byte
Status (Byte 8)
0 = OK
1 = ERROR
2 = Invalid Command
3 = Invalid Parameter
Command Name (bytes
Name of the
command
The HEX (non-ASCII) value
of the requested register
17-18)
Value (Byte(s) 9-n)
If present, indicates the requested
parameter value to set the given
register. If no characters present,
the register is queried.
Command Data (byte 19-n)
     29