DLP-IOR4 DLP Design Inc, DLP-IOR4 Datasheet

MODULE LATCHING-RELAY 4-CH

DLP-IOR4

Manufacturer Part Number
DLP-IOR4
Description
MODULE LATCHING-RELAY 4-CH
Manufacturer
DLP Design Inc
Series
DLP-IOR4r
Datasheet

Specifications of DLP-IOR4

Accessory Type
Module Latching Relay
Interface Type
USB
Operating Supply Voltage
220 V
Product
Interface Modules
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
USB
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
813-1011
Applications:
- Data-Acquisition
- Industrial/Process
- Home Automation
- Robotics
1.0 INTRODUCTION
The DLP-IOR4 is a low-cost, easy-to-use relay module utilized for computer control of electrical or
electronic equipment.
Note: The relays used on the DLP-IOR4 are latching type relays. As such, the state of the relay will
not change when power is removed from the module.
All operational power is taken from the host PC via the USB port.
2.0 SPECIFICATIONS
Each of the four relays on the DLP-IOR4 has the following specifications:
Note: The two sets of contacts for each relay were connected in parallel to achieve these ratings.
Rev. 1.1 (September 2007)
Control
Control
Contact Ratings: 120W, 250VA
Max Switching Voltage: 220VDC, 250 VAC
Max Switching Current: 4A
Max Carrying Current: 4A
USB-BASED LATCHING RELAY MODULE
- Easy to Use with Single-Byte Commands;
Features:
- 4 Latching Relays
- USB Port Powered
- USB 1.1 and 2.0 Compatible Interface
- Small Footprint: 4.1 x 0.96 Inch PCB
Can Utilize a Simple Terminal Emulator to
Control All Functions
1
D
D
LEAD-FREE
L
L
P
P
© DLP Design, Inc.
-
-
I
I
O
O
R
R
4
4

Related parts for DLP-IOR4

DLP-IOR4 Summary of contents

Page 1

... The DLP-IOR4 is a low-cost, easy-to-use relay module utilized for computer control of electrical or electronic equipment. Note: The relays used on the DLP-IOR4 are latching type relays. As such, the state of the relay will not change when power is removed from the module. All operational power is taken from the host PC via the USB port. ...

Page 2

... Manager under Ports (COM & LPT). 6.0 USING THE DLP-IOR4 Simply connect the DLP-IOR4 to the PC to initiate the loading of drivers. Once the drivers are loaded, the DLP-IOR4 is ready for use. All commands are single-byte commands. Please note that the Ping command is the only command that results in data being returned to the host from the DLP-IOR4. ...

Page 3

... MECHANICAL DIMENSIONS IN INCHES (MM) (PRELIMINARY) .96 typ (24.4 typ) Rev. 1.1 (September 2007 Return / Comments R (0x52) will be returned if the DLP-IOR4 is found on the selected port. 4.1 typ (104 typ 75.0 typ (1.9m typ © DLP Design, Inc. ...

Page 4

... This product and its documentation are supplied on an as-is basis, and no warranty as to their suitability for any particular purpose is either made or implied. DLP Design, Inc. will not accept any claim for damages whatsoever arising as a result of the use or failure of this product. Your statutory rights are not affected ...