AT90CAN128-16AJ Atmel, AT90CAN128-16AJ Datasheet - Page 346

IC MCU AVR FLASH 128K 64TQFP

AT90CAN128-16AJ

Manufacturer Part Number
AT90CAN128-16AJ
Description
IC MCU AVR FLASH 128K 64TQFP
Manufacturer
Atmel
Series
AVR® 90CANr
Datasheets

Specifications of AT90CAN128-16AJ

Core Processor
AVR
Core Size
8-Bit
Speed
16MHz
Connectivity
CAN, EBI/EMI, I²C, SPI, UART/USART
Peripherals
Brown-out Detect/Reset, POR, PWM, WDT
Number Of I /o
53
Program Memory Size
128KB (128K x 8)
Program Memory Type
FLASH
Eeprom Size
4K x 8
Ram Size
4K x 8
Voltage - Supply (vcc/vdd)
2.7 V ~ 5.5 V
Data Converters
A/D 8x10b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
64-TQFP, 64-VQFP
For Use With
ATDVK90CAN1 - KIT DEV FOR AT90CAN128 MCU
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT90CAN128-16AJ
Manufacturer:
Atmel
Quantity:
10 000
25.6.7
25.6.8
25.6.9
25.6.10
346
AT90CAN32/64/128
Reading the EEPROM
Programming the Fuse Low Bits
Programming the Fuse High Bits
Programming the Extended Fuse Bits
The algorithm for reading the EEPROM memory is as follows (refer to
on page 342
The algorithm for programming the Fuse Low bits is as follows (refer to
on page 342
The algorithm for programming the Fuse High bits is as follows (refer to
Flash” on page 342
The algorithm for programming the Extended Fuse bits is as follows (refer to
Flash” on page 342
1. A: Load Command “0000 0011”.
2. G: Load Address High Byte (0x00 - 0xFF).
3. B: Load Address Low Byte (0x00 - 0xFF).
4. Set OE to “0”, and BS1 to “0”. The EEPROM Data byte can now be read at DATA.
5. Set OE to “1”.
1. A: Load Command “0100 0000”.
2. C: Load Data Low Byte. Bit n = “0” programs and bit n = “1” erases the Fuse bit.
3. Give WR a negative pulse and wait for RDY/BSY to go high.
1. A: Load Command “0100 0000”.
2. C: Load Data Low Byte. Bit n = “0” programs and bit n = “1” erases the Fuse bit.
3. Set BS1 to “1” and BS2 to “0”. This selects high data byte.
4. Give WR a negative pulse and wait for RDY/BSY to go high.
5. Set BS1 to “0”. This selects low data byte.
1. A: Load Command “0100 0000”.
2. C: Load Data Low Byte. Bit n = “0” programs and bit n = “1” erases the Fuse bit.
3. Set BS1 to “0” and BS2 to “1”. This selects extended data byte.
4. Give WR a negative pulse and wait for RDY/BSY to go high.
5. Set BS2 to “0”. This selects low data byte.
for details on Command and Address loading):
for details on Command and Data loading):
for details on Command and Data loading):
for details on Command and Data loading):
“Programming the Flash”
“Programming the Flash”
“Programming the
“Programming the
7679H–CAN–08/08