HD64F3672FY Renesas Electronics America, HD64F3672FY Datasheet - Page 233

IC H8 MCU FLASH 16K 48QFP

HD64F3672FY

Manufacturer Part Number
HD64F3672FY
Description
IC H8 MCU FLASH 16K 48QFP
Manufacturer
Renesas Electronics America
Series
H8® H8/300H Tinyr
Datasheet

Specifications of HD64F3672FY

Core Processor
H8/300H
Core Size
16-Bit
Speed
16MHz
Connectivity
SCI
Peripherals
PWM, WDT
Number Of I /o
26
Program Memory Size
16KB (16K x 8)
Program Memory Type
FLASH
Ram Size
2K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 5.5 V
Data Converters
A/D 4x10b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
48-QFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD64F3672FY
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD64F3672FYV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
14.3.2
ADCSR consists of the control bits and conversion end status bits of the A/D converter.
Bit
7
6
5
4
3
Bit Name
ADF
ADIE
ADST
SCAN
CKS
A/D Control/Status Register (ADCSR)
Initial Value
0
0
0
0
0
R/W
R/W
R/W
R/W
R/W
R/W
Description
A/D End Flag
[Setting conditions]
[Clearing condition]
A/D Interrupt Enable
A/D conversion end interrupt (ADI) request enabled
by ADF when 1 is set
A/D Start
Setting this bit to 1 starts A/D conversion. In single
mode, this bit is cleared to 0 automatically when
conversion on the specified channel is complete. In
scan mode, conversion continues sequentially on
the specified channels until this bit is cleared to 0 by
software, a reset, or a transition to standby mode.
Scan Mode
Selects single mode or scan mode as the A/D
conversion operating mode.
0: Single mode
1: Scan mode
Clock Select
Selects the A/D conversions time
0: Conversion time = 134 states (max.)
1: Conversion time = 70 states (max.)
Clear the ADST bit to 0 before switching the
conversion time.
When A/D conversion ends in single mode
When A/D conversion ends on all the channels
selected in scan mode
When 0 is written after reading ADF = 1
Rev.4.00 Nov. 02, 2005 Page 207 of 304
Section 14 A/D Converter
REJ09B0143-0400

Related parts for HD64F3672FY