HD64F3672FY Renesas Electronics America, HD64F3672FY Datasheet - Page 216

IC H8 MCU FLASH 16K 48QFP

HD64F3672FY

Manufacturer Part Number
HD64F3672FY
Description
IC H8 MCU FLASH 16K 48QFP
Manufacturer
Renesas Electronics America
Series
H8® H8/300H Tinyr
Datasheet

Specifications of HD64F3672FY

Core Processor
H8/300H
Core Size
16-Bit
Speed
16MHz
Connectivity
SCI
Peripherals
PWM, WDT
Number Of I /o
26
Program Memory Size
16KB (16K x 8)
Program Memory Type
FLASH
Ram Size
2K x 8
Voltage - Supply (vcc/vdd)
3 V ~ 5.5 V
Data Converters
A/D 4x10b
Oscillator Type
Internal
Operating Temperature
-20°C ~ 75°C
Package / Case
48-QFP
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HD64F3672FY
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Part Number:
HD64F3672FYV
Manufacturer:
Renesas Electronics America
Quantity:
10 000
Section 13 Serial Communication Interface 3 (SCI3)
Rev.4.00 Nov. 02, 2005 Page 190 of 304
REJ09B0143-0400
[4]
Figure 13.13 Sample Serial Reception Flowchart (Clocked Synchronous Mode)
Yes
No
Read receive data in RDR
Clear OER flag in SSR to 0
Clear RE bit in SCR3 to 0
Read RDRF flag in SSR
Overrun error processing
Read OER flag in SSR
All data received?
Error processing
Start reception
RDRF = 1
OER = 1
<End>
<End>
Yes
No
No
(Continued below)
Error processing
Yes
[1]
[2]
[3]
[4]
[1]
[2]
[3]
[4]
Read the OER flag in SSR to determine if
there is an error. If an overrun error has
occurred, execute overrun error processing.
Read SSR and check that the RDRF flag is
set to 1, then read the receive data in RDR.
When data is read from RDR, the RDRF
flag is automatically cleared to 0.
To continue serial reception, before the
MSB (bit 7) of the current frame is received,
reading the RDRF flag and reading RDR
should be finished. When data is read from
RDR, the RDRF flag is automatically
cleared to 0.
If an overrun error occurs, read the OER
flag in SSR, and after performing the
appropriate error processing, clear the OER
flag to 0. Reception cannot be resumed if
the OER flag is set to 1.