TLE6230GP Infineon Technologies, TLE6230GP Datasheet - Page 8

IC SW SMART OCTAL LOWSIDE PDSO36

TLE6230GP

Manufacturer Part Number
TLE6230GP
Description
IC SW SMART OCTAL LOWSIDE PDSO36
Manufacturer
Infineon Technologies
Type
Low Sider
Datasheet

Specifications of TLE6230GP

Input Type
SPI
Number Of Outputs
8
On-state Resistance
800 mOhm
Current - Peak Output
1.5A
Voltage - Supply
4.5 V ~ 5.5 V
Operating Temperature
-40°C ~ 150°C
Mounting Type
Surface Mount
Package / Case
DSO-36
Switch Type
Low Side
Power Switch Family
TLE6230
Input Voltage
-0.3 to 7V
Power Switch On Resistance
800mOhm
Output Current
1A
Mounting
Surface Mount
Supply Current
1mA
Package Type
DSO
Operating Temperature (min)
-40C
Operating Temperature (max)
150C
Operating Temperature Classification
Automotive
Pin Count
38
Power Dissipation
3300W
Packages
PG-DSO-36
Thermal Class
Heatslug down
Id Nom
8 x 0.5 A
Channels
8.0
Comment
relay driver and general purpose
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Current - Output / Channel
-
Lead Free Status / Rohs Status
Compliant
Other names
SP000012169
SP000691114
TLE6230GP
TLE6230GPNT
TLE6230GPT
TLE6230GPT
TLE6230GPTR

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TLE6230GP
Manufacturer:
INFINEON
Quantity:
1 210
Part Number:
TLE6230GP
Manufacturer:
INFINEON
Quantity:
804
Part Number:
TLE6230GP
Manufacturer:
INFINEON/英飞凌
Quantity:
20 000
Power Transistor Protection Functions
Each of the eight output stages has its own zener clamp, which causes a voltage limitation at
the power transistor when solenoid loads are switched off. The outputs are provided with a
current limitation set to a minimum of 1 A. The continuous current for each channel is 500 mA
(all channels ON).
Each output is protected by embedded protection functions. In the event of an overload or
short to supply, the current is internally limited and the corresponding bit combination is set
(early warning). If this operation leads to an overtemperature condition, a second protection
level (about 170 °C) will change the output into a low duty cycle PWM (selective thermal shut-
down with restart) to prevent critical chip temperatures.
SPI Signal Description
pin. Whenever the pin is in a logic low state, data can be transferred from the µC and vice
versa.
To avoid any false clocking the serial clock input pin SCLK should be logic low state during
high to low transition of CS . When CS is in a logic high state, any signals at the SCLK and SI
pins are ignored and SO is forced into a high impedance state.
SCLK - Serial Clock. The system clock pin clocks the internal shift register of the TLE
6230 GP. The serial input (SI) accepts data into the input shift register on the falling edge of
SCLK while the serial output (SO) shifts diagnostic information out of the shift register on the
rising edge of serial clock. It is essential that the SCLK pin is in a logic low state whenever chip
select CS makes any transition. The number of clock pulses will be counted during a chip se-
lect cycle. The received data will only be accepted, if exactly 16 clock pulses were counted
during CS is active.
SI - Serial Input. Serial data bits are shifted in at this pin, the most significant bit first. SI infor-
mation is read in on the falling edge of SCLK. Input data is latched in the shift register and then
transferred to the control buffer of the output stages.
The input data consists of two bytes - a "control byte” followed by a "data byte". The control
byte contains the information as to whether the data byte will be accepted or ignored (see di-
agnostics section). The data byte contains the input information for the eight channels. A logic
8)
nently
V2.3
CS - Chip Select. The system microcontroller selects the TLE 6230 GP by means of the CS
CS High to Low transition: - diagnostic status information is transferred from the power
CS Low to High transition: - transfer of SI bits from shift register into output buffers
The integrated protection functions prevent an IC destruction under fault conditions and may not be used in normal operation or perma-
- serial input data can be clocked in from then on
- SO changes from high impedance state to logic high or low
- reset of diagnosis register
outputs into the shift register.
state corresponding to the SO bits
8)
Page
8
Data Sheet TLE 6230 GP
18. Nov. 2009