ADE7758ARW Analog Devices Inc, ADE7758ARW Datasheet - Page 43

no-image

ADE7758ARW

Manufacturer Part Number
ADE7758ARW
Description
IC ENERGY METERING 24-SOIC
Manufacturer
Analog Devices Inc
Datasheet

Specifications of ADE7758ARW

Rohs Status
RoHS non-compliant
Input Impedance
380 KOhm
Measurement Error
0.1%
Voltage - I/o High
2.4V
Voltage - I/o Low
0.8V
Current - Supply
8mA
Voltage - Supply
4.75 V ~ 5.25 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
24-SOIC (0.300", 7.50mm Width)
Meter Type
3 Phase
Lead Free Status / RoHS Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
ADE7758ARW
Quantity:
1 000
Part Number:
ADE7758ARWZ
Manufacturer:
AD
Quantity:
517
Part Number:
ADE7758ARWZ
Manufacturer:
AD
Quantity:
53
Part Number:
ADE7758ARWZ
Manufacturer:
AD
Quantity:
1 000
Part Number:
ADE7758ARWZ
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
ADE7758ARWZRL
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Gain Calibration Using Pulse Output
Gain calibration is used for meter-to-meter gain adjustment,
APCF or VARCF output rate calibration, and determining the
Wh/LSB, VARh/LSB, and VAh/LSB constant. The registers used
for watt gain calibration are APCFNUM (0x45), APCFDEN
(0x46), and xWG (0x2A to 0x2C). Equation 50 through
Equation 52 show how these registers affect the Wh/LSB
constant and the APCF pulses.
END
YES
WATT OFFSET
ALL PHASES
CAL?
SET UP PULSE
WATT OFFSET
@ I
OUTPUT FOR
CALIBRATE
A, B, OR C
NO
MIN
, PF = 1
YES
ALL PHASES
VAR OFFSET
CAL?
SET UP PULSE
@ I
OUTPUT FOR
VAR OFFSET
CALIBRATE
Figure 76. Calibration Using Pulse Output
INDUCTIVE
A, B, OR C
NO
MIN
YES
, PF = 0,
PHASE ERROR
Rev. D | Page 43 of 72
PHASES
CAL?
ALL
START
PHASE @ I
SET UP PULSE
OUTPUT FOR
CALIBRATE
INDUCTIVE
A, B, OR C
For calibrating VAR gain, the registers in Equation 50 through
Equation 52 should be replaced by VARCFNUM (0x47),
VARCFDEN (0x48), and xVARG (0x2D to 0x2F). For VAGAIN,
they should be replaced by VARCFNUM (0x47), VARCFDEN
(0x48), and xVAG (0x30 to 0x32).
Figure 77 shows the steps for gain calibration of watts, VA, or
VAR using the pulse outputs.
NO
PF = 0.5,
YES
TEST
GAIN CAL
PHASES
,
VAR?
ALL
@ I
SET UP FOR
CALIBRATE
INDUCTIVE
A, B, OR C
NO
VAR GAIN
TEST
PHASE
YES
, PF = 0,
CALIBRATE VRMS
CALIBRATE IRMS
VA AND WATT
GAIN CAL?
PHASES
OFFSET
OFFSET
ALL
HAVE SEPARATE PULSE OUTPUTS
PF = 1 BECAUSE THEY
CAN BE CALIBRATED
SIMULTANEOUSLY @
SET UP PULSE
WATT AND VA
GAIN @ I
OUTPUT FOR
WATT AND VA
CALIBRATE
A, B, OR C
NO
PF = 1
MUST BE DONE
BEFORE VA GAIN
CALIBRATION
TEST
ADE7758
,