STFPC311BTR STMicroelectronics, STFPC311BTR Datasheet - Page 18

IC CTRL/DRIVER FRONT PNL 52-PQFP

STFPC311BTR

Manufacturer Part Number
STFPC311BTR
Description
IC CTRL/DRIVER FRONT PNL 52-PQFP
Manufacturer
STMicroelectronics
Datasheet

Specifications of STFPC311BTR

Display Type
Vacuum Fluorescent (VF)
Interface
Serial
Current - Supply
5mA
Voltage - Supply
3 V ~ 33.3 V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
52-MQFP, 52-PQFP
Maximum Operating Temperature
+ 85 C
Maximum Clock Frequency
1 MHz
Maximum Output Current
25 mA
Maximum Power Dissipation
1200 mA
Minimum Operating Temperature
- 40 C
Mounting Style
SMD/SMT
For Use With
497-8394 - BOARD DEMO STFPC311/ST72264497-6454 - BOARD EVAL BASED ON STFPC311
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Configuration
-
Digits Or Characters
-
Lead Free Status / Rohs Status
 Details
Other names
497-6107-2

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
STFPC311BTR
Manufacturer:
TI
Quantity:
200
Part Number:
STFPC311BTR
Manufacturer:
STMicroelectronics
Quantity:
10 000
Part Number:
STFPC311BTR
Manufacturer:
ST
Quantity:
4 000
Part Number:
STFPC311BTR
Manufacturer:
ST
0
Part Number:
STFPC311BTR
Manufacturer:
ST
Quantity:
20 000
6 Commands
6
6.1
Table 3.
Note:
18/39
Commands
A command sets the display mode and status of the VFD driver. The first 1-byte input to the
STFPC311 through the D
set to high while commands/data are transmitted, the serial communication is initialized and the
commands/data being transmitted are invalid (however, the commands/data already
transmitted remain valid).
Configuration mode setting command
This command initializes the STFPC311 and performs any one of the following functions see
Figure 14.
Figure 14. STFPC311 Configuration mode setting command order
Based on Bit 5 through Bit 4 settings.
STFPC311 Configuration mode bit 3 through bit 0 settings
a)
b)
c)
d)
Selects the number of segments and number of grids (1/8 to 1/16 duty, 12 segments
to 20 segments). When this command is executed, the display is turned off. To
resume display, the Display ON command must be executed. If the same mode is
selected, nothing is performed.
Selects the remote control protocol to use.
Sets the watchdog timer. The watchdog timer is configurable from 1s to 15s or turned
off completely.
Sets the watchdog action to perform when the watchdog timer counts. Two actions
are allowed: no action, and set STBY to (logic) high level.
IN
pin after the STB pin goes low is regarded as a command. If STB is
STFPC311

Related parts for STFPC311BTR